Troubleshooting; Specifications - SDMO HX 7500 T IP54 Instruction And Maintenance Manual

Table of Contents

Advertisement

9. Troubleshooting

Problems
Load connected to the generating set during start-up.
Oil level too low.
Unsuitable fuel.
Fuel level too low.
Engine not
starting
Fuel tap (fig. A - No. 5) closed.
Air filter (fig. A - No. 6) clogged.
Defective spark plug (fig. F - No. 2).
Fuel supply blocked or leaking.
Oil level too low.
Engine stopped
Fuel level too low.
Blocked ventilation inlets.
Circuit breakers (fig. A - No. 10) tripped.
Defective appliance supply cord.
No electric
current
Defective electrical sockets (fig. A - No. 11).
Defective alternator.
Device connected or faulty cord.
Triggering of
circuit breakers
Overload (see § Capacity of the generating set).
No working
Working hours counter fuse (fig. A - No. 13) faulty.
hours counter

10. Specifications

Model
Maximum output / Rated output
Sound pressure level at 1 m (LpA)
Engine type
Recommended fuel
Fuel tank capacity
Recommended oil
Oil sump capacity
Oil failure cut-out
Circuit breaker
Direct current
Alternating current
Socket type
Spark plug type
Battery
Dimensions l x w x h
Weight (without fuel)
● : standard
○ : option
AVR: The AVR system (Automatic Voltage Regulation) enables a more efficient stabilisation of the generating set voltage.
Probable causes
X: not possible
Possible solutions
Disconnect the load.
Check the oil level and top up if necessary
(see § Checking the oil level).
Change the fuel (see § Specifications).
Fill up with fuel (see § Filling with fuel).
Open the fuel tap.
Clean the air filter (see § Cleaning the air filter).
Check the spark plug (see § Checking the spark plug)
and replace if necessary.
Have it checked, repaired or replaced.*
Check the oil level and top up if necessary
(see § Checking the oil level).
Fill up with fuel (see § Filling with fuel).
Clean the generating set (see § Cleaning the
generating set).
Trip the circuit breakers.
Change the cord.
Have it checked, repaired or replaced.*
Have it checked, repaired or replaced.*
Disconnect the device and the cord.
Remove the overload.
Have it checked, repaired or replaced.
* Operation(s) to be entrusted to one of our agents.
HX 7500 T AVR IP54
6000 W / 4800 W
96 dB(A)
Honda GX 390
Unleaded petrol
6.1 L
SAE 10W30
1.1 L
X
230V - 10A et 400V - 7A
2 x 2P+T 230V 10/16A - 1 x 3P+T+N 400V 16A
NGK : BPR6ES / DENSO : W20EPR-U
X
77 x 57 x 59 cm
101 kg