Troubleshooting; Specifications - SDMO TECHNIC 15000 TE C Instruction And Maintenance Manual

Hide thumbs Also See for TECHNIC 15000 TE C:
Table of Contents

Advertisement

9. Troubleshooting

Problems
Load connected to the generating set during start-up.
Oil level too low.
Oil filter (fig. B - No. 4) clogged.
Unsuitable fuel.
Fuel tap (fig. A - No. 6) closed.
Engine not
starting
Fuel filter (fig. C - No. 3) clogged.
Air filter (fig. A - No. 7) clogged.
Defective spark plug (fig. E - No. 2).
Faulty starter battery (fig. A - No. 13).
Fuel supply blocked or leaking.
Oil level too low.
Engine red light indicator is turned on.
Engine stopped
Fuel level too low.
Blocked ventilation inlets.
Circuit breakers (fig. A - No. 11) not actuated.
Defective appliance supply cord.
No electric
current
Defective electrical sockets (fig. A - No. 12).
Defective alternator.
Device connected or faulty cord.
Triggering of
circuit breakers
Overload (see § Capacity of the generating set).
No working
Working hours counter fuse (fig. A - No. 15) faulty.
hours counter

10. Specifications

Model
Maximum output / Rated output
Sound pressure level at 1 m (LpA)
Engine type
Recommended fuel
Fuel tank capacity
Recommended oil
Oil sump capacity
Oil failure cut-out
Circuit breaker
Direct current
Alternating current
Socket type
Spark plug type
Battery
Dimensions l x w x h
Weight (without fuel)
● : standard
○ : option
AVR: The AVR system (Automatic Voltage Regulation) enables a more efficient stabilisation of the generating set voltage.
Probable causes
X: not possible
Disconnect the load.
Check the oil level and top up if necessary
(see § Checking the oil level).
Replace the oil filter (see § Replacing the oil filter).
Change the fuel (see § Specifications).
Open the fuel tap.
Replace the fuel filter (see § Replacing the fuel filter).
Clean the air filter (see § Cleaning the air filter).
Check the spark plug (see § Checking the spark plug)
and replace if necessary.
Recharge or replace the starter battery.
Have it checked, repaired or replaced.*
Check the oil level and top up if necessary
(see § Checking the oil level).
Check the oil level and top up if necessary
(see § Checking the oil level).
Fill up with fuel (see § Filling with fuel).
Clean the generating set (see § Cleaning the
generating set).
Actuate the circuit breakers.
Change the cord.
Have it checked, repaired or replaced.*
Have it checked, repaired or replaced.*
Disconnect the device and the cord.
Remove the overload.
Have it checked, repaired or replaced.
* Operation(s) to be entrusted to one of our agents.
TECHNIC 15000 TE C
11000 W / 8800 W
Kohler CH 640S
Unleaded petrol
1x2P+T 230V 10/16A - 1x2P+T 230V 16A - 1x3P+T+N 400V 16A
CHAMPION : RC12YC
89.5 x 57 x 77 cm
Possible solutions
TECHNIC 15000 TE AVR C
88 dB(A)
35 L
SAE 10W30
1.9 L
X
400V - 12.7A
146 kg

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents