Mounting; Mounting Instructions; Mounting Preparations; Installation Procedure - KROHNE OPTISWITCH 5100 C Handbook

Vibrating level switch
Hide thumbs Also See for OPTISWITCH 5100 C:
Table of Contents

Advertisement

4 Mounting

Installation procedure

6
4
Mounting
4.1

Mounting instructions

If the electronics module is defective, it can be replaced by the user.
In Ex applications, only instruments and electronics modules with ap-
propriate Ex approval may be used.
4.2

Mounting preparations

In general, the electronics module can be also exchanged within the
type series against an electronics with another signal output (e.g.
relay against transistor output).
If you want to use an electronics module with a different signal output,
you can download the corresponding operating instructions manual
on our homepage under Downloads.
4.3
Installation procedure
To exchange the electronics module, proceed as follows:
1. Switch off voltage supply
2. Unscrew the housing lid
3. Lift the opening levers of the terminals with a screwdriver
4. Pull the connection cables out of the terminals
5. Loosen the two screws with a screw driver (Torx size T10 or slot
4)
Fig. 1: Loosen the holding screws
1
Electronics module
2
Screws (2 pcs.)
6. Pull out old electronics module
7. Compare the new electronics module with the old one. The type
label of the electronics module must correspond to that of the old
electronics module. This applies particularly to instruments used
in hazardous areas.
8. Compare the settings of the two electronics modules. Set the
adjustment elements of the new electronics module to the same
setting of the old one.
Electronics module • OPTISWITCH 5100 C, 5150 C, 5200 C, 5250 C
1
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optiswitch 5150 cOptiswitch 5200 cOptiswitch 5250 c

Table of Contents