E.
Liquid Level Transmitter Assembly, PN 13503-106 (refer to IPL Figure 5) as follows:
(1)
List of Materials
NOTE:
ITEM
Sealant
Safety Wire
Twine
(2)
Procedure
(a)
Assemble bridge PC board (125) to light driver PC board (130) by aligning guide pins
and pressing assemblies together.
(b)
Install grommets (100) on banana plugs of bridge PC board (125) with spongy side of
grommet adjacent to PC board.
(c)
Assemble mounting plate (80) on bridge PC board (125) with tab on base indexed in
hole in PC board. Use screws (85), nylon washers (90), washers (95), ground wire lug
(105), spacers (110 and 115) and threaded supports (20) to secure mounting plate (80)
to PC boards. Use Loctite, Grade C, sealant on threads of screws (85).
(d)
Install ground wire assembly into the harness on light driver PC board (130) using
lacing twine on wire bundle.
(e)
Connect lug (120) of light driver PC board (130) wire bundle to receptacle (70) of case
(5). Turn retaining ring to lock plug to receptacle.
Monogram Sanitation
COMPONENT MAINTENANCE MANUAL
PN 15900-012 Series
Equivalent substitutes may be used.
DESCRIPTION
No. 404 & Grade C per
MIL-S-22473
MS20995C20 per
MS35540
.06 Wide Nylon per MIL-
T-713
SOURCE
Loctite Company
300 N. Mountain Road
Newington, CT 06111
Commercially Available
Commercially Available
38-31-07
Page 711
Jan 10/95