Monogram 15900-012 Assembly page 32

Table of Contents

Advertisement

3.
Cleaning Procedures
A.
Toilet Assembly
(1)
Support the toilet tank drain outlet over a suitable waste receptacle or drain.
WARNING: A FACE GUARD AND GLOVES SHOULD BE WORN DURING ALL
(2)
Clean the external and internal surfaces of the bowl assembly using either a solution of
hot, soapy water and strong disinfectant or a steam cleaner.
(3)
Remove the bowl assembly and the separator assembly (refer to DISASSEMBLY).
(4)
Open the drain valve to the fully compressed position by pulling on the valve cable
assembly and clamp or otherwise secure the cable assembly in this position. Do not
crimp the cable.
CAUTION: EXERCISE CARE TO AVOID PROLONGED APPLICATION OF
(5)
Steam clean all interior surfaces of the tank, back flush through the flushing motor
pump outlet channel, which is exposed when the bowl is removed, and through the vent
and flushing openings.
(6)
Drain all liquid from the tank assembly.
(7)
Dry all surfaces of the tank and internal components with dry, compressed air.
CAUTION: DO NOT USE HYDROCARBON SOLVENTS, CHEMICAL
(8)
If additional cleaning of subassemblies and detail parts is required after removal from
the tank assembly, use a soap, disinfectant, and hot water solution and a stiff-bristled
brush.
Monogram Sanitation
COMPONENT MAINTENANCE MANUAL
PN 15900-012 Series
STEAM CLEANING FOR PROTECTION FROM SPLASHBACK.
STEAM TO ANY PLASTIC SURFACES.
SOLVENTS OF THE ETHER OR FLUORIDE FAMILY, ACETONE,
METHYL-ETHYL-KETONE, OR RELATED SOLVENTS ON ANY
KEVLAR Or PLASTIC PARTS. DO NOT USE ABRASIVE OR
SCOURING CLEANSER ON NAY METAL, FIBERGLASS OR
PLASTIC PARTS.
38-31-07
Page 402
Jan 10/95