COMPONENT MAINTENANCE MANUAL
B.
Motor-Pump-Filter Assembly
(1)
Use a soft bristle brush to dislodge solid wastes and lubricants.
CAUTION: DO NOT PERMIT SOLVENT ON STATOR OR ROTOR WINDINGS,
(2)
Remove adhesives and sealants by carefully scraping residue from surface and wiping
surface with cloth moistened with solvent.
(3)
Remove dust and dirt form the housing and stator assembly and the rotor assembly
with dry, compressed air.
(4)
Dry all parts with dry, compressed air after cleaning.
C.
Drain Valve Assembly
The valve assembly may be cleaned by immersing and scrubbing the unit in a solution of
soap and water or five tablespoons of liquid disinfectant to each gallon (3.78 liter) of water.
Rinse thoroughly with hot water and dry using compressed air.
D.
Timer Assembly
Because the timer is sealed when installed, minimal internal cleaning should be required
unless the assembly is contaminated during disassembly and subsequent overhaul procedures.
Blow dust or other foreign particles from internal parts. If necessary, use a soft-bristled brush
to dislodge stubborn particles.
E.
Liquid Level Transmitter
Because the transmitter is sealed when installed, minimal internal cleaning should be
required unless the assembly is contaminated during disassembly and subsequent overhaul
procedures. Blow dust or other foreign particles from internal parts. If necessary, use a soft-
bristled brush to dislodge stubborn particles.
Monogram Sanitation
PN 15900-012 Series
OR THE ELECTRICAL LEADS, AS SOLVENT TENDS TO
PRECIPITATE DETERIORATION OF WIRE INSULATION
38-31-07
Page 403/404