Monogram 15900-012 Assembly page 35

Table of Contents

Advertisement

1.
General
A.
The complete assembly and component subassemblies shall be visually inspected using a
strong light and preferably some means of magnification. When inspecting for damage to
interior details of an assembly, an inspection mirror shall be used so that all surfaces are
made visible.
B.
All parts shall be visually examined for nicks, cracks, cuts, fraying, dents, distortion, chafing,
scoring, excessive wear, loose or missing mounting rings and screws, stripped or crossed
threads and other defects that could impair function of the toilet. Parts made of rubber or
neoprene shall be replaced at each overhaul; therefore, inspection of rubber packings, seals,
mushroom valve an gaskets is unnecessary.
C.
To conduct an electrical check of Liquid Level Transmitter Assembly PN 13503-106 refer to
schematic diagram in Figure 501.
D.
Refer to schematic diagram, Figure 502 to check continuity of electrical wiring on Timer
Assembly PN 11059-79.
E.
Conduct a detailed inspection of parts and assemblies in accordance with the requirements of
Inspection and Check, Table 501.
Monogram Sanitation
COMPONENT MAINTENANCE MANUAL
PN 15900-012 Series
CHECK
38-31-07
Page 501
Jan 10/95