Avdel 07900-09080 Instruction Manual

Avdel 07900-09080 Instruction Manual

Broach load test power tool

Advertisement

Quick Links

I n s t r u c t i o n M a n u a l
O r i g i n a l i n s t r u c t i o n
0 7 9 0 0 - 0 9 0 8 0
S p e e d F a s t e n i n g A p p l i c a t i o n s
B ro a c h L o a d Te s t P o w e r To o l

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 07900-09080 and is the answer not in the manual?

Questions and answers

Summary of Contents for Avdel 07900-09080

  • Page 1 I n s t r u c t i o n M a n u a l O r i g i n a l i n s t r u c t i o n 0 7 9 0 0 - 0 9 0 8 0 S p e e d F a s t e n i n g A p p l i c a t i o n s B ro a c h L o a d Te s t P o w e r To o l...
  • Page 3: Table Of Contents

    In the event of a defect or failure, and at its sole discretion, Avdel UK Limited undertakes only to repair or replace faulty components. Avdel UK Limited policy is one of continuous product development and improvement and we reserve the right to change the specification of any product without prior notice.
  • Page 4: Safety Rules

    14 When carrying the tool from place to place keep hands away from the trigger/lever to avoid inadvertent start up. 15 The combination of fastener, mandrel, hole size and sheet thickness shall be in accordance with specifications set by Avdel UK Limited.
  • Page 5: Tool Specifications

    Tools can be purchased under part number 07900-09080 or you may contact your local Avdel representative to test your application. The test tool can be used to define the ideal combination of tool/nose equipment/fastener for your application and in any case MUST be used prior to the actual placing tool in order to define the broach load exerted on the mandrel when placing a fastener in the...
  • Page 6: Putting Into Service

    P u t t i n g i n t o S e r v i c e A i r S u p p l y This tool operates with compressed air at a maximum pressure of 7 bar. We recommend that you temporarily make use of the air supply set up for your actual placing tool with precautions as described in the instruction manual for your placing tool.
  • Page 7: Operating Procedure

    I M P O R T A N T The test tool MUST be returned to Avdel UK Limited at minimum every 6 months for re-calibration. A new manual with an updated air pressure versus broach load graph will be supplied in English and in the official language of your country if EC regulations apply.
  • Page 8: Air Pressure Graph Vs Broach Load

    A i r P re s s u re G r a p h v s B ro a c h L o a d...
  • Page 9: Mandrel Life Table

    M a n d re l L i f e Ta b l e...
  • Page 10 N o t e s...
  • Page 11 D e c l a r a t i o n o f C o n f o r m i t y We, Avdel UK Limited, Watchmead Industrial Estate, Welwyn Garden City, Herts, AL7 1LY declare under our sole responsibility that the product: Model: Broach Load Test Power Tool Serial No.
  • Page 12 This document is for informational purposes only. Infastech makes no warranties, expressed or implied, in this document. Data shown is subject to change without prior notice as a result of continuous product development and improvement policy. Your local Avdel representative is at your disposal should you need to confirm latest information.