  • Page 1 I n s t r u c t i o n M a n u a l 7 4 2 0 0 T h r e a d e d I n s e r t P o w e r To o l...
  • Page 3: Table Of Contents

    AND REMEDIES. ANY IMPLIED WARRANTY AS TO QUALITY, FITNESS FOR PURPOSE, OR MERCHANTABILITY ARE HEREBY SPECIFICALLY DISCLAIMED AND EXCLUDED BY AVDEL. Avdel UK Limited policy is one of continuous product development and improvement and we reserve the right to change the specification of any product without prior notice.
  • Page 4: Safety Rules

    Any modification undertaken by the customer to the tool/machine, nose assemblies, accessories or any equipment supplied by Avdel UK Limited or their representatives, shall be the customer’s entire responsibility. Avdel UK Limited will be pleased to advise upon any proposed modification.
  • Page 5: Tool Specifications

    S p e c i f i c a t i o n s To o l S p e c i f i c a t i o n Air Pressure Minimum - Maximum 5-7 bar (75-100 lbf/in Free Air Volume Required @ 5 bar/75 lbf/in 8 litres (.28 ft Stroke...
  • Page 6: Intent Of Use

    flow-line assembly in a wide variety of applications throughout all industries. A complete tool is made up of the base tool (part number 74200-12000) and the appropriate nose assembly for the insert, as described on page 9.
  • Page 7: Putting Into Service

    P u t t i n g i n t o S e r v i c e A i r S u p p l y All tools are operated with compressed air at an optimum pressure of 5.5 bar. We recommend the use of pressure regulators and automatic oiling/filtering systems on the main air supply.
  • Page 8: Nose Assemblies

    Any worn or damaged part should be replaced by a new part. • Particularly check wear on drive screw. • Assemble according to fitting instructions. * Refers to items included in the 74200 service kit. For complete list see page 11.
  • Page 9: Selection

    Places all inserts listed in this section except M5 large flange Thin Sheet Nutsert® •• Places M5 large flange Thin Sheet Nutsert® 09698-00516 ONLY † These nose assemblies include an adaptor nut part number 74200-12119 to replace the one on the tool.
  • Page 10: Servicing The Tool

    S e r v i c i n g t h e To o l Regular servicing should be carried out and a comprehensive inspection performed annually or every 500,000 cycles, whichever is sooner. I M P O R T A N T The employer is responsible for ensuring that tool maintenance instructions are given to the appropriate personnel.
  • Page 11: Service Kit

    S e r v i c i n g t h e To o l S e r v i c e K i t For all servicing we recommend the use of the service kit (part number 74200-99990) supplied in its own plastic case. SERVICE KIT...
  • Page 12: Maintenance

    Remove circlip 97 from double male connector 41 using circlip pliers and withdraw sintered filter 96. • Assemble in reverse order of dismantling. * Refers to items included in the 74200 service kit. For complete list see page 11. Item numbers in bold refer to the General Assembly drawing and parts list (pages 14-15).
  • Page 13: Differential Valve

    Priming is ALWAYS necessary after the tool has been dismantled and prior to operating * Refers to items included in the 74200 service kit. For complete list see page 11. Item numbers in bold refer to the General Assembly drawing and parts list (pages 14-15).
  • Page 14: General Assembly Of Base Tool

    G e n e r a l A s s e m b l y o f B a s e To o l 7 4 2 0 0 - 1 2 0 0 0...
  • Page 15 P a r t s L i s t f o r 7 4 2 0 0 - 1 2 0 0 0...
  • Page 16: Priming

    P r i m i n g Priming is ALWAYS necessary after the tool has been dismantled and prior to operating. It may also be necessary to restore the full stroke after considerable use, when the stroke may be reduced and fasteners are not fully placed by one operation of the trigger. O i l D e t a i l s The recommended oil for priming is Hyspin VG32 available in 0.5l (part number 07992-00002) or one gallon containers (part number 07992-00006).
  • Page 17: Fault Diagnosis

    Hold tool square to application when placing Insert continued overleaf Item numbers in bold refer to general assembly drawings and parts list (pages 14-15). Other symptoms or failures should be reported to your local Avdel authorised distributor or repair centre.
  • Page 18 Lubricate tool at air inlet. If insufficient dismantle and clean air motor thoroughly Item numbers in bold refer to general assembly drawings and parts list (pages 14-15). Other symptoms or failures should be reported to your local Avdel authorised distributor or repair centre.
  • Page 19 D e c l a r a t i o n o f C o n f o r m i t y We, Avdel UK Limited, Watchmead Industrial Estate, Welwyn Garden City, Herts, AL7 1LY declare under our sole responsibility that the product: Model Type 74200 Serial No.
  • Page 20 Tel: +82 31 798 6340 Email: info@acument.com.au Email: AvdelDeutschland@acument.com Fax: +82 31 798 6342 Email: info@acumentkorea.com CANADA ITALY Avdel Canada, a Division of Acument Avdel Italia S.r.l. SPAIN Canada Limited Viale Lombardia 51/53 Avdel Spain S.A. 87 Disco Road 20047 Brugherio (MI)