Mounting A Fan Unit; Reassembling The Server - Sun Microsystems SPARC Series Service Manual

Table of Contents

Advertisement

13.3

Mounting a Fan Unit

Caution – Do not forcibly mount a fan unit in a slot. Forcibly pushing a fan unit in
a slot may damage the fan unit or the server.
1. Adjust the position of the fan unit so that its latch is on the right when you are
facing the front of the server.
2. Insert the fan unit in the slot.
13.4

Reassembling the Server

1. Attach the fan cover.
For details, see
2. Slide the server into the equipment rack and secure the stabilizer bar.
For details, see
page
3. From the XSCF shell prompt, use the showhardconf command to verify that
the new fan unit has been installed.
XSCF> showhardconf
For details, see
Section 5.4.2, "Attaching the Fan Cover" on page
Section 5.1.2, "Sliding the Server into the Equipment Rack" on
5-3.
Section 4.4.2, "Verifying the Hardware Operation" on page
5-8.
Chapter 13
Fan Unit Replacement
4-10.
13-5