Testing the ES8105/ES8105F

You can use the following information to verify that the RocketLinx ES8105/ES8105F is functioning properly.
1.
Use the
Hardware Installation
2.
Apply power to the ES8105/ES8105F.
3.
Verify that the PWR LED is lit.
4.
Connect one side of an Ethernet cable (Category-5 or above straight-through Ethernet cable with RJ45 connectors to
connect network devices.) with an RJ45 connector to the ES8105/ES8105F Ethernet port (RJ45 port), and the other side of
the Ethernet cable to the target device with a configured IP address and capable of supporting the ICMP protocol, such as
ping packets.
Note: Make sure that any connected network switches support MDI/MDIX functionality. If they do not, use an Ethernet
crossover cable.
5.
Verify that the port status LED indicator is blinking green on the RocketLinx ES8105/ES8105F to see if the network
connection was established successfully.
6.
Power on your host PC, make an Ethernet connection to RocketLinx ES8105/ES8105F and verify that the connected port
is lit. The connection diagram is shown below:
IP Address: 192.168.11.10
Host
PC
7.
Open a Command Line window by clicking Run in Start menu, type command, and then click Ok to continue.
8.
For example, type ping 192.168.11.102 to check the connection. The IP address for the remote device in this
example is: 192.168.11.102.
9.
Repeat Step 8 to make sure that the connection of each device connected to the ES8105/ES8105F is properly established.
Testing the ES8105/ES8105F
section on Page 7 to install the ES8105/ES8105F.
ES8105
Ping 192.168.11.102 -t
Ethernet Cable
ES8105F
Reply 192.168.11.10
Power Supply
Ping 192.168.11.102 -t
or
Ethernet Cable
Reply 192.168.11.10
RocketLinx ES8105/ES8105F User Guide: 2000558 Rev. B - 11
IP Address: 192.168.11.102
Target
Device