Description
2.6

External residual-current device

The manufacturer does not supply an external residual-current device. If an external
residual-current device is required because of local rules, this section helps you to
select the correct device.
Situation: the local rules require an immunity for short current peaks over PE
during the EV charging process
At the start of the EV charge cycle, a relay switches and engages the AC input power
to the power modules. Incidental current peaks can occur. For the specifications of
the current peaks, refer to section
A combination of these factors is the source of these current peaks:
Asynchronous engagement of the phases in the relay
The electrical capacity of the AC input power part of the EVSE
The amplitude of the current peaks can change. These factors are the source of the
differences:
The location of the EVSE
The power grid
The earth impedance
18
8.15
.
BCM.S1102.0-EN | 001