Ethernet cable
Parameter
Ethernet type
Cable type
Example of a cable for distance of 75 m
or less
Bandwidth, upload
Bandwidth, download
Availability
8.12
AC input specifications
8.12.1
General AC input specifications
Parameter
Input AC power connection
Earthing systems
Input voltage range
Power factor at full load
Efficiency
Total harmonic distortion (current)
8.12.2
AC input cable
Parameter
Cable shielding (optional)
Diameter of the phase conductors
Diameter of the PE conductor
Surface
Diameter, including shielding
8.12.3
Terra 94
Parameter
Maximum rated input current
BCM.S1102.0-EN | 001
Specification
RJ45
8P + PE, shielded
HELUKAT 600E
Minimum 128 kbit/s
Minimum 4 Mbit/s
99.9%
Specification
3P + N + PE
TN-S
TN-C
TN-C-S
IT
400 VAC +/- 10% (50 Hz or 60 Hz)
> 0.96
> 94% at nominal output power
< 5%
Specification
If the local rules require shielded cables,
the cable shielding must be connected
to the PE rail at both ends of the cable.
Refer to the local rules.
The same as the diameter of the phase
conductors
minimum 150 mm²
34 to 45 mm
Specification [A]
140
Technical data
45