The unit must be earthed. A special terminal marked
17.
for this purpose.
This product is intended for use at a maximum altitude of 3,000 m.
18.
The user manual for this unit is available from the after-sales service.
19.
Do not dispose your water heater in the garbage, but hand it to a place
20.
assigned for this purpose (collection point) where it can be
recycled.
EN

INSTALLATION

1.
MOUNTING
For the installation of the product, refer to diagram 1 page 2
2.
HYDRAULIC CONNECTION
For the hydraulic connection of the product, refer to diagram 2 page 3.
- The supply pipes must be cleaned thoroughly before performing the hydraulic connection. The connection on the hot water outlet must be
undertaken using a cast iron or steel sleeve or a dielectric pipe joint in order to avoid corrosion of the pipe (direct contact iron/copper). Use of a
brass joint is prohibited.
- Depending on the nominal pressure, a new 0.7 or 0.9 MPa (7 or 9 bar) safety device measuring ½" or ¾" must be installed on the water heater
inlet in compliance with the standards in force (EN 1487 in Europe)
.
ATTENTION: Every time the water is heated, an outflow occurs from the tap: do not block this outflow. If supplied, the safety device does not
satisfy the installation criteria in France (mainland and DOM TOM overseas territories): do not use.
3.
ELECTRICAL CONNECTION
For the electrical connection of the product, refer to diagram 3 page 4.
- The water heater can only be connected to and operated via a 220-240 VAC alternating current. Connect the water heater using a rigid conductor
cable with section 2.5 mm². For this purpose, use a standardised pipe (fixed or fluted sheath) up to the calibrated housing of the cover.
- Connect units fitted with a cable or outlet directly. In France, a product with a cable and outlet is strictly prohibited and cannot be sold or installed.
- The earth conductor of the cable must be earthed or the earth wire must be connected to the relevant terminal marked by the symbol
This connection is essential for safety reasons. The green-yellow earth wire must be longer than the live wires. The installation must include an
all-pole cut-off device upstream of the supply tank (contact opening at least 3 mm: circuit breaker, fuse). If the hydraulic hoses are made from
an insulating material, the electrical circuits will be protected by a 30 mA differential circuit breaker complying with the standards in force.
Thermal circuit breaker (see diagram 5 page 4): All our products are fitted with a thermostat with a manual-reset thermal circuit breaker which
cuts the power supply to the water heater in the event of overheating. If safety device is triggered A: Switch the power supply off before any
performing operation. B: remove the cover. C: Check the electrical connection. D: Reset the safety device. In the event of repeated triggering,
replace the thermostat. Never short-circuit the safety device or the thermostat. Only connect the power supply to the terminal or the thermostat
input.
See "Warnings" no.1 to no.6
see "Warnings" no.10 to no.14