Technical data
AgilE 2, AgilE 3
Type
Size
Output, motor side
Recommended motor shaft power
Output current
Long-term overload current (60 s)
Short-term overload current (1 s)
Output voltage
Protection
Rotating field frequency
Switching frequency
Brake-chopper integrated
Output, brake resistor
Min. brake resistance
Recommended brake resistor
Input, mains side
Mains configuration
Rated current
Maximum mains current
Mains voltage range
Mains frequency
[UL type 600 VAC RK5]
Fuses
Overvoltage category
Influencing factors
Energy dissipation
(at 2 kHz switching frequency)
Coolant temperature (air)
Communication
Connection X21
Serial data interface. RS485 communication via VABus or Modbus protocol.
CAN system bus
Control terminals, CAN interface ISO-DIS 11898.
RS232, RS485, Profibus-DP or CANopen.
Optional module
Storage
Digital memory card
Save and transfer parameter values via standard memory card.
401-15
3.0
kW
A
7.5
A
11.2
A
15.0
3-phase. Input voltage as max. output value.
V
Short-circuit proof/earth fault proof
0 ... 1000, depending on switching frequency
Hz
2, 4, 8, 16
kHz
Yes
106
(770 V)
148
TT, TN, IT
6.8
A
A
9.8
(EN 61800-5-1)
380 (-15%) ... 480 (+10%)
V
45 ... 69
Hz
[10]
A
10
EN 50178 III, DIN EN 61800-5-1 III
W
133
°C
0 ... 40 (40 ... 55 with derating)
400 V
3
401-18
401-19
401-21
2
3
4.0
7.5
5.5
9.5
13.0
17.0
14.2
19.5
25.5
19.0
26.0
34.0
106
48
48
106
80
58
7.8
14.2
15.8
12.8
17.2
23.0
[10]
[20]
[20]
10
25
25
167
235
321
15
401-22
401-23
9.2
11.0
20.0
23.0
30.0
34.5
38.0
46.0
48
48
48
48
26.0
28.1
33.6
[30]
[40]
35
35
393
470
GB
Need help?
Do you have a question about the Agile AGL 401-05 and is the answer not in the manual?