3 | Technical Information

Heating element
Voltage
Wattage
Temperature setting
IP Rating
Appliance class
Power cable length

4 | Installation

The Ecostrad Ecowärme Electric Radiator should be mounted on a
load-bearing wall using the fixings provided. Always observe the minimum
safety clearances stated in Table 2.
Between the sides of the radiator and any
masonry
Between the sides of the radiator and
flammable materials
From the radiator to the floor
From the top of the radiator to any covering
above

4-1 | Wall mounting instructions

1. Read all safety instructions and warnings stated in the preceding section
of this manual. Failing to follow these instructions can cause damage to
life or property.
2. Remove all packaging, making sure no packaging residue remains on the
radiator.
3. Drill four holes in the wall as per Table 3, Figure 1 and the drilling template
provided with radiator.
Ecostrad_Ecowärme_V1.2_09022022
Table 1 | Specifications
Range
Resolution
Table 2 | Minimum safety distances
If flammable (i.e wooden window sill)
If non-flammable (i.e brick alcove)
X-bar element and ceramic core
230V AC / 50 Hz
500W, 1000W, 1200W, 1500W,
2000W
5-30 °C
0.5 °C
IP20
Class I
1.5m
5cm
10cm
8cm
15cm
10cm