Page 1
Ecostrad Ecowärme Electric Radiator PLEASE READ AND SAVE THESE INSTRUCTIONS...
Page 2
Symbols Warning This symbol indicates a hazard with an average risk level which, if not avoided, could result in serious injury or death. Warning of electrical voltage This symbol indicates danger to the life and health of persons due to electrical voltage.
1 | About the Manual This manual describes the Ecostrad Ecowärme Electric Radiator and details how to install and use the product. It is important to thoroughly review this manual before using the product. For additional information regarding any aspect of the Ecostrad Ecowärme Electric Radiator, contact: Ecostrad Ltd.
Page 5
Warning In order to avoid a hazard due to inadvertent re-setting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility. Warning Do not cover the radiator, nor place flammable objects on the radiator.
Page 6
• The device must only be installed in an upright and fixed position in accordance with national installation rules. • Do not use the radiator with a programmer, timer, separate remote control system or any other device that switches the heater on automatically, since a fire risk exists if the heater is covered or positioned incorrectly.
Class I Power cable length 1.5m 4 | Installation The Ecostrad Ecowärme Electric Radiator should be mounted on a load-bearing wall using the fixings provided. Always observe the minimum safety clearances stated in Table 2. Table 2 | Minimum safety distances...
4. Insert the wall-plugs and screws into the wall. 5. Hang the radiator on the screws. 4-2 | Feet fixing instructions The Ecostrad Ecowärme Electric Radiator can become free-standing when the optional feet are purchased. These feet come in white or anthracite, to match the radiator.
Page 9
Figure 2 | Feet fixing holes on compatible models 1. Slot the feet into the ribs and line up the holes, as in Figure 3. Figure 3 | Fixing the feet 2. Fix in place with 6 screws, as in Figure 4. Figure 4 | Feet successfully attached Ecostrad_Ecowärme_V1.2_09022022...
5 | Control Panel 5-1 | Display The Ecowärme control panel features a backlit display, as shown in Figure 5. The backlight engages when any key is pressed, and will time out when not in use. The default time-out length is 90 seconds, but this can be adjusted (see section 5-5-3). Symbol Meaning Standby Comfort...
5-2 | Setting the time When you first turn on your Ecostrad Ecowärme Electric Radiator, the display will prompt you to set the time and date. The screen shows 00:00 and the numbers 1-7 flashing, with an arrow pointing to 1.
Page 12
5-4-1 | Comfort mode When the icon displays on the screen, you are in Comfort mode. In this mode, the radiator controls the room temperature and heats to a constant set temperature. The thermostat measures the ambient temperature and instructs the radiator to heat or stop heating according to the temperature set.
Page 13
5-4-4 | Auto mode When the icon and program bars appear on the screen, you are in Auto mode. In this mode, the element follows a user-customisable program. The program consists of 24 hourly slots for each day of the week which can be set to Comfort , Eco or Frost...
5-4-5 | Timer mode In this mode, the radiator will heat to a set temperature for a certain amount of time. When the timer ends, the radiator will return to Auto mode. To enter Timer mode: 1. Press MODE to move to Auto mode 2.
Page 15
the temperature and the icon. Now press and hold the Standby Button for 10 seconds. The numbers 1-7 will appear on the right side of the screen. 5-5-1 | Eco mode settings The first option of the advanced settings, indicated by an arrow pointing to 1, is the Eco mode setting.
Page 16
Whichever option is selected, you can use the icon to view the alternate temperature. to choose between 0 and 1. Here, 0 = display of room temperature (indicated by ) and 1 = display of set temperature. Press to confirm and move to the next setting. 5-5-5 | Open window detection The fifth option, indicated by the arrow pointing to 5, is the Open window detection setting.
3-year guarantee on the paintwork, and a 2-year guarantee on electrical components. Within the stated period, starting from the date the customer receives their unit, Ecostrad guarantee to repair or replace the unit where a fault is due to defects in materials or manufacturing.
warranty – provided evidence can be produced that the work was performed by a qualified installer – no compensations will be offered for the installer’s costs in the event of a claim. Claims must be made with the establishment where the device was purchased. This warranty does not affect the customer’s consumer rights.
Table 5 | Information requirements for electrical local space heaters Item Unit Type of heat output/room temperature control (select one) single stage heat output and no room temperature control [no] Two or more manual stages, no room temperature control [no] with mechanic thermostat room temperature control [no] with electronic room temperature control...
Need help?
Do you have a question about the Ecowarme and is the answer not in the manual?
Questions and answers