Chapter 4 Timer Functions
RMCTR
90
Timer Function Control Registers
(3) Remote control carrier output control register (RMCTR)
7
6
5
4
–
–
–
–
RMOEN
Figure 4-9-19 Remote Control Carrier Control Register
3
2
1
0
–
–
RMDTY0
(RMCTR: X'03F89', R/W)
(at reset: ---00XX0)
Must be set to "0."
Remote control carrier
RMDTY0
output duty selection
0
1/2 duty
1
1/3 duty
Must be set to "0."
Enable remote control
RMOEN
carrier output
0
Output low level
1
Output remote control carrier
Must be set to "0."