Electric circuit
Permissible connection methods
CAUTION:
Voltage of heating elements
230V.
Each connection requires the
protective ground of the mains
to be connected to the
terminal.
1
For 220-240VAC mains
single-phase connection with
operating neutral conductor.
Jumpers connecting the
terminals 1-2-3. Jumper to
the terminals 4-5 for the
operation neutral conductor.
Protective conductor on
2
For 220-240VAC mains
two-phase connection with
operating neutral conductor.
Jumpers connecting the
terminals 1-2. Jumper to
the terminals 4-5 for the
operation neutral conductor.
Protective con-ductor on
3
For 220-240VAC mains
three-phase connection with
operating neutral conductor.
Jumpers connecting 4-5.
Phase sequence according
to 1-2-3. Jumper to the
terminals 4-5 for the
operation neutral conductor.
Protective conductor on
L1, L2, L3 = Phase

Connecting the hob

Insert the plug located at the end of the hob's cable
bundle into the respective sockets on the oven switch
panel.
PE
.
.
.
N = Neutral
EN-18
Recommended
connection
method
H05VV-F
3 G 6.0 mm
H05VV-F
4 G 6.0 mm
H05VV-F
5 G 2.5mm
PE = Protective ground
2
2
2