Flushing of Sediment and Draining
To flush or drain the water heater, power must be turned off, then turn off the cold water supply to the unit. The
lever on the TPR valve should be opened but care should be taken to the lever does not snap back as it could
damage the valve seat. The pressure in the water heater will be released when the lever is opened. The union at
the cold water inlet to the water heater should be undone and a hose should be attached to the water heater side
of the union. The other end of the hose should go to a drain.
Opening the TPR valve allows air into the water heater and for the water to drain. Following complete draining of
the water heater, the closest hot water taps may be opened fully and the TPR valve closed with care. Following
reconnection at the cold water inlet, the cold water stop valve is now opened fully and the water heater may be
filled with cold water and flushed through to ensure the cylinder contains no sediment and is clean. Finally the
closest hot taps are closed and power may be turned on again to the completely filled water heater.
In the event of an anomaly – the heater does not heat or steam is released from the TPR valve – switch off the
electric power supply and contact your reseller.
Domestic/User Maintenance
Water heaters do not require much domestic maintenance by the user. Operate the TPR valve once a month to
eliminate any residue of scaling and check that it is not blocked. Open and close the TPR valve slowly to avoid
damage to the seal.
WARNING: Failure to operate the TPR valve at least once every six months may mask a problem with the water
heater. Continuous leakage of water from the TPR valve may indicate a problem with the water heater. Any damage
caused due to not regularly operating the TPR valve may invalidate the warranty.
It is not unusual for the TPR valve to allow a small quantity of water to escape during the heating cycle and this
must be left open to the atmosphere.
Maintenance by a qualified person
Remove the scale sludge. Do not scrape or chip at lime scale deposited on the casing because this may damage the
lining. Change the magnesium anode every 2 years or when its diameter is less than 10mm. Changing the heating
element or the anode requires the water heater to be drained and the seal changed.
Draining the Tank
Turn off the power and the supply of cold water. Open the hot water faucets and manipulate the safety TPR valve
before performing these operations. Refit the heating element and tighten the screws gently (opposite screws in
sequence). Check for leaks the next day and tighten if required.
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer
or approved service agent.

Replacement Parts

Replacement parts are the thermostat, seals, heating element, boiler shell, indicator light, magnesium anode and
connection cable. The warranty requires genuine manufacturer's parts to be used.