EN
Your water heater: Wiring diagrams
2.4.
Steatite stable model components
200 L
2.5.
Shielded horizontal model components
3.
Specifi c installation procedures
3.1.
Adjusting the temperature
The factory temperature setting is 65° C.
The temperature may be lowered
by turning the wheel.
4.
Specifi c maintenance conditions
4.1.
Parts that can be replaced
• Thermostat
• Cover
• Heater body (only for Steatite water heaters)
The seal must be replaced if the heater body is replaced or opened.
Any replacement operation must be performed by a qualifi ed person using
the manufacturer's original parts.
Thermostat
Thermal
safety mechanism
Heater element
Power supply cable
Thermostat
Thermal safety mechanism
Power supply cable
+ +
- -
- -
• Heater element
• Seal
250 and 300 L
Potentiometer
- -
+
+
+ +
59