Feider Machines FP225-KET User Manual page 9

Plaster sander
Table of Contents

Advertisement

4). Position the new abrasive pad on the rear disc, making sure that the center hole in the abrasive disc is in
the middle of the rear abrasive disc.
5). Position the large metal washer of the retaining nut on the sander.
6). Rotate the retaining nut clockwise and tighten by hand (while holding the abrasive pad).
The output shaft is inserted at the centre of the adhesive disc with six angle wrench with clockwise rotation
angle in the six hexagonal holes, and at the same time, the hands hold the adhesive disc. The grinding disc
can be remove adhesive.
TO CONNECTED WITH THE DUST COLLECTING BAG
In order to protect the operator to reduce dust suction and site cleaning process at work, in the work process
please connect the machine with dust bag. As shown in the figure is connected with the suction pipe, the
other end is connected with the dust collecting bag.
CAUTION: Failure to use a dust bag rated for drywall dust will increase the level of airborne dust particles in
the work area. Continued and prolonged exposure to high concentrations of airborne dust may affect the
respiratory system function.
EMPTYING THE DUST BAG
Warning: Only empty the dust bag when the machine is switched" off". The dust bag has an open seam
which is sealed by a plastic slide fastener.
IF THE BAG IS 50% FULL OF DUST, PLEASE EMPTY THE DUST BAG TIMELY.