Ferlux HIDROMATIC Manual page 43

Automatic pellet boiler
Table of Contents

Advertisement

ALARM
DESCRIPTION
CODE
Er17
Air flow regulation not achieved
Er23
Probe body water stove
Flow meter sensor
Er39
The minimum airflow has not been
Er41
reached during the "Check- up"
Excessive airflow during
Er42
"Check-up" (Check)
Er52
Error module I/O 12C
broken
check
POSSIBLE CAUSE
We could have a problem in
the smoke outlet
The air inlet is totally or
partially plugged, or has been
channeled and has a lot of
pressure loss
Dirty brazier
The boiler takes air from an
unstrained entrance: open or
poorly closed door, hopper
without pellet, etc.
The smoke passages of the
boiler are very dirty
The smoke extractor has lost
potency
Problems with the flow
sensor
or its connection
(Sond message appears)
Airflow sensor broken
Defective or poorly wired
probe
It could appear when the
boiler is turned off if the flow
sensor breaks down during
operation
We could have a problem in
the smoke outlet
The air inlet is totally or
partially plugged, or has been
channeled and has a lot of
pressure loss
Dirty brazier
The boiler takes air from an
unstrained entrance: open or
poorly closed door, hopper
without pellet, etc.
The fume passages of the
boiler are dirty
The smoke extractor has lost
its potency
Problems with
the flow or
its connection (the message
Sond)
It could appear if we had an
excessive shot in the chimney,
or if we are forcing the air inlet
for combustion.
Point-in-time
communication
failure between the connection
module and the electronic
board
43
SOLUTION
Review all the possibilities listed
in the Er02 Check the boiler and
installation
Check the cleanliness of the boiler
and the smoke outlet In case of
repeating this alarm very often or
not being able to reset it, notify
the Technical Service
Notify the Technical Service
If this problem persists the Er41
will appear
Review all the possibilities listed
in the Er02 Check the boiler and
installation
Check the cleanliness of the boiler
and the smoke outlet In case of
repeating this alarm very often or
not being able to reset it, notify
the Technical Service
Review and correct installation In
case of repeating this alarm
often, or not getting
reset it, notify the Technical
Service
Disconnect a few seconds from
the mains and reconnect If this is
repeated often
alarm, or you can not reset,
notify the S.A.T. (Technical
Service)