Fuel Loading; Starting Up - Ferlux HIDROMATIC Manual

Automatic pellet boiler
Table of Contents

Advertisement

7.2 FUEL LOADING

The fuel load will be done by the top of the hopper
The use of fuels other than those indicated and the use of the boiler as an incinerator are prohibited.
The use of pellets in poor condition or any other product not recommended can damage some
components of the boiler, impairing its operation. This will result in the cessation of the warranty and
the corresponding liability of the manufacturer..
It is important that the level of pellet in the fuel hopper is periodically monitored, to prevent it from
emptying completely and shutting down the boiler with the error of lack of fuel.
The manufacturer recommends always having it at least half load.
.
After a long period of inactivity, it will be necessary to remove the remains of pellets from the fuel
tank since these could have absorbed moisture, changing their original characteristics and may not
be suitable for use.
7.3 COMMISSIONING
IN ORDER TO VALIDATE THE START-UP,
IT MUST BE CARRIED OUT BY AN OFFICIAL FERLUX TECHNICAL SERVICE.
The following should also be considered before proceeding to the first ignition of the boiler:
1.
Proceed to the loading of fuel as indicated in the previous section.
2.
Close the boiler door.
3.
Check that the installation is filled with water.
4.
Connect the boiler to the mains and turn it on from the general switch, located at the back of it right next to where
the plug of the power outlet is. The "Stopped" operating status will appear on the screen.
36

Advertisement

Table of Contents
loading

Table of Contents