Electrical Connection; Connection Of The External Thermostat - Ferlux HIDROMATIC Manual

Automatic pellet boiler
Table of Contents

Advertisement

5.6 ELECTRICAL CONNECTION

For the installation of the boiler, the power outlet must be in accordance with the specific applicable legal regulations.
The boiler is supplied with power cable that must be connected to the 230V socket. We must make sure that the general switch
of the boiler is at 0 and then connect the cable to the power, first behind the boiler and then to the electrical outlet.
The installation of the boiler must be in accordance with the specific applicable legal regulations, with adduced amperage. We
must ensure that the power cord, in its final position, does not encounter hot or sharp parts that may deteriorate it.
The power outlet must be single-phase with phase, neutral and grounding.
If the mains voltage is not sinusoidal (such as generator sets or other equipment) the boiler could give problems
and operating errors.
5.7 EXTERNAL THERMOSTAT CONNECTION (Normally Closed)
If you want to connect an external ambient thermostat, it is mandatory that it has a minimum hysteresis of 2ºC to avoid
unnecessary switching on and off of the boiler, leading to operating problems.
When the ambient thermostat opens contact, for the circulation pump, the boiler has a waiting time
before going into standby. If the water temperature exceeds 75 °C the pump works again to cool
down.
When the ambient thermostat closes the contact, the boiler has a waiting time before
Starts the ignition again.
24

Advertisement

Table of Contents
loading

Table of Contents