9. PROBLEMS, MESSAGES AND ALARMS

Below are some tips to make sure that everything is correct before turning on the boiler, and start with the maximum
guarantees: A malfunction of the boiler is usually accompanied by an alarm or even a message, although this is not always
the case. Below we expose some cases that may arise, in which some checks can be made before notifying the Technical
Service.
When connecting the boiler, the differential of the house is triggered. The first thing would be to reconnect the
boiler in another plug, and if the problem persists it could be humidity in any of the components of the boiler, so
we should make sure that moisture does not reach the boiler through the environment and / or the chimney, wait
several hours until it restarts and if the problem continues plese call the Technician.
The screen does not turn on. Check that the voltage reaches the plug, see if the back switch is on, the switch fuse
may be blown, etc.
ON DAYS OF STRONG WIND OR ADVERSE WEATHER CONDITIONS,
COMBUSTION IN THE BOILER MAY NOT BE GOOD DUE TO THE INFLUENCE
ON THE CHIMNEY DRAFT. THE MANUFACTURER IS NOT RESPONSIBLE
FOR THE MALFUNCTION OF THE BOILER UNDER ADVERSE ATMOSPHERIC
CONDITIONS.
9.2 MESSAGES

MESSAGE

Sond
Clean
Service
Ignition Lock
MESSAGE DESCRIPTION
Visualization of the status of temperature probes,
flow sensor or pressure transducer. The message
appears during the"Check up" phase, and indicates
that the temperature, airflow, pressure transducer
measurement present some anomaly.
Ordinary maintenance: the boiler displays this
message after 150 h of operation to perform ordinary
maintenance by the user.
Extraordinary maintenance: the boiler shows this
message after 2000 h of operation to perform
extraordinary maintenance by the S.A.T.
This message is displayed by the boiler if it is turned
off non-manually in the "On" phase (after preloading)
39
SOLUTION
Check the status and connection
of the probes.
Notify Technical Service if the
message persists.
See section 6.1.2
CONFIGURATIONS - Reset
Service
Notify the Technical Service to
do the extraordinary cleaning and
reset the hours of service.
The boiler finishes the ignition and
turns off when the working regime
is reached. Remove the message
and turn it back on.