The boiler is equipped with
installation. The installer will be in charge of verifying that the maximum pressure existing at each point of the
installation does not exceed the maximum working pressure of each component. The installation of the discharge
pipe of the safety valve should be carried out in such a way that it does not impede its regular operation and does
not cause harm to people. It must be accessible.
DO NOT install the boiler in a primary system with an open expansion tank.
For the heating of possible radiant panels at low temperature an inertia tank (puffer) installed according to the
manufacturer's instructions is required.
Perform the filling and filling of the system through the charging tap (not exceeding 1.8 bar).
It is possible that in the first days of operation it is necessary to purge more than once so that all the air that may be
in the installation comes out.
Direct connection
boiler.
The temperature of return for the water in the boiler must be higher than
phenomena.
The water characteristics on the installation are very important for the proper functioning and
the boiler.
One of the most notable drawbacks is the fouling on the heat exchange surfaces.
Lime scale considerably reduces heat exchange due to its low thermal conductivity.
The installer must decide, according to the type of water and
is recommended for the following cases:
-
High water hardness
-
Very extensive facilities
-
Successive fillings due to maintenance work of the installation or produced by losses.
For the treatment of feed water from thermal installations it is recommended to always contact an authorized installer.
Do not remove water from the installation or empty the boiler of water except in extreme cases of
maintenance or repair. In no case will the boiler water be used for domestic use.
IT IS MANDATORY, THE INSTALLATION OF AN AUTOMATIC BLEEDER TO AVOID ANY KIND OF
PROBLEMS CAUSED BY AIR IN THE HEATING CIRCUIT.
THIS INSTALLATION WILL REMOVE ANY ACCUMULATED AIR FROM THE HEATING SYSTEM, THIS
WILL MAKE BOTH THE BOILER AND THE RADIATOR CIRCUIT WORK CORRECTLY
IT IS MANDATORY, THE INSTALLATION OF AN ANTI-CONDENSATION VALVE AT 55 ° C TO AVOID
CONDENSATION PROBLEMS.
THE INSTALLATION OF THE ANTI-CONDENSATION VALVE WILL PREVENT THE WATER RETURN
FROM BEING IN TEMPERATURES LOWER THAN 55 ° C, AND THEREFORE WILL MAKE THE BOILER
AND THE HYDRAULIC CIRCUIT WORK CORRECTLY.
a
safety valve at
Radiant panels should not directly receive water from the boiler.
to radiators is prohibited,
22
3 bar to act on occasional increases in pressure in the
since
their small diameter prevents proper operation of the
installation if it includes water treatment, this
50-55 ºC to avoid
condensation