5.4 HOME FIRE PREVENTION
The manufacturer's instructions for both the installation and use of the boiler must be complied with, in addition to
all the corresponding safety regulations and regulations must also be complied with. Otherwise, FERLUX is not
responsible in the event of any accident.
It is recommended to have out of the heat focus (at least 1.5m away) any combustible or flammable element such
as wooden
beams, furniture, curtains, flammable liquids, etc. A protective
combustible material should be
in place.
Periodic cleaning of the boiler and the smoke ducts must be carried out since the soot and other accumulated
combustion residues could enter into combustion.
In the event of a chimney fire, use the appropriate extinguishing systems to put out the fire, or contact the firefighters
for their intervention.
If fumes occur during the operation of the boiler, ventilate the room, and check the tightness of the elements of the
same and the chimney. Once verified if the problem persists consult with the SAT to adopt a solution.
In the case of having a flammable floor (parquet type, floating flooring.) or heat-sensitive soils, it is necessary
to place a protection that separates the stove from the ground. This protection should be of a fire-resistant material
such as marble, sheet
of the boiler. It shall be at least 2 mm and shall be at least 150 mm from the boiler on the sides and rear and 300
mm from the front of the stove.
Below is a table with the minimum safety distances that must always be guaranteed on a mandatory basis
A
B
C
D
5.4.1 MEASURES TO CROSS ENCLOSURES
The smoke duct must cross one or more enclosures of the premises
be installed.
The size of the holes that need to be
Once the tube has passed the remaining space must be filled with insulation (rock wool, ceramic fiber.)
Wall in flammable wood, or with
flammable parts
Cement wall or ceiling
Brick wall or ceiling
placed in the heat focus area where flammable or heat-sensitive coatings are
steel, tiles, etc. This material has to be able to
Safety distances to flammable
material
200 mm
1500 mm
500 mm
opened depends on the diameter of the duct and the enclosure to be crossed.
Insulating thickness
Distancias de seguridad al material
no inflamable
Safety distances to non-flammable
depending on
Diameter of holes to be made
[mm]
[mm] for an outlet tube Ø80 mm
100
50
30
16
layer of insulating and
resist without breaking due to the weight
material
100 mm
750 mm
200 mm
where the device is going to
280
180
140
non-