5.7 HYDRAULIC CONNECTION

The hydraulic installation must be carried out by qualified personnel,respecting the current installation regulations (RITE).
The hydraulic connection depends on the type of installation, although there are several "rules" that are common for all
types of installations.
The installation and hydraulic connection must be done by qualified personnel who can issue the documentation of
a correct installation according to the regulations in force in each country. FERLUX is not responsible for damages
arising from erroneous connections or made by unqualified personnel.
If the installation provisions are not respected, the product warranty expires and FERLUX is excluded from all liability
related to damage to persons or things
The entire range of FERLUX boilers with automatic cleaning is equipped with a closed expansion vessel.
The expansion vessel incorporated in the boiler does NOT guarantee adequate protection from thermal expansions
suffered by water throughout the installation. Therefore, it will be the qualified installer who will have to determine the
need for an additional expansion vessel, depending on the type of installation planned.
Suitable traps and devices must be placed for the proper evacuation of air from the circuit in the boiler filling phase.
It is recommended to interspersing cutting keys between the installation and the boiler, to simplify maintenance work.
The installation of an inertia tank (puffer) is recommended but not mandatory. This has the advantage of decoupling
the boiler from sudden demands, reduces consumption and increases the efficiency of the system.
The hot water should be "directed" differently depending on the objectives (radiators, exchanger,
buffer,etc.).
The material used in the circuit must be suitable to withstand possible excesses of temperature and pressure.
Ø 60 mm
Ø 110 mm