General Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative
humidity at 0 % to 90 %.
Extended specifications are available at www.fluke.com.
Maximum voltage between any terminal
and earth ground ........................................................... 600 V
W Fuse for A input (115 only) ...................................... F 11 A, 1 000 V, Interrupt Rating: 17 kA
Display ........................................................................... Digital: 6 000 counts, updates 4/sec
Temperature .................................................................. Operating: -10 °C to + 50 °C
Temperature Coefficient ............................................... 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)
Operating Altitude ......................................................... 2 000 meters
Battery ........................................................................... 9 V Alkaline, NEDA 1604A / IEC 6LR61
Battery Life .................................................................... Alkaline: 400 hours typical, without backlight
IP Rating (dust and water protection) .......................... IP42 (non-operation)
Safety ............................................................................. IEC 61010-1: Pollution Degree 2
20
(Fluke PN 803293)
Bar Graph: 33 segments, updates 32/sec
Storage: -40 °C to + 60 °C (limited by battery
specification)
IEC 61010-2-033: CAT III 600 V

Advertisement

Table of Contents
loading

This manual is also suitable for:

115 plus

Table of Contents