36/57
Commissioning and operation
7.3

Operation

Bosch Rexroth AG R911336186_Edition 02
Please observe the general safety instructions on the protection against haz‐
ardous movements
chapter 2.6.2 "Protection from mechanical danger" on
page
4.
During operation, keep the ambient and operation conditions as well as the
technical data specified in the project planning manual
Housing Motors MAD/MAF.
Checks during operation:
Pay attention to exceptional noise.
Pay attention to increased vibrations.
Check the motors and fan units for cleanliness.
Check the tightness of the coolant connections.
Check the monitoring devices and diagnostic / error messages of the con‐
trollers.
Decommission the drive when deviations from normal operation exist. For
further procedure refer to
MAD / MAF Asynchronous Housing Motors
chapter 12 "Troubleshooting" on page
Asynchronous
45.