MAD / MAF Asynchronous Housing Motors
1
A1
2
A2
X5
3
A3
GN/YE
8
5
TM+/MotoTemp+
6
TM-/MotTemp-
X6
7
Br+/+24VBr
8
Br-/0VBr
①
Device connector INS480 (view of plug-in side)
②
Connector socket INS380 (view of plug-in side)
③
Coupling
④
Device connector
⑤
Only one PTC sensor is applied (spare sensor lines are in the
socket housing)
⑥
Holding brake (option)
⑦
Overall shield connection by clamping the cables of the strain
relief in the connector
⑧
Connection designations on the Rexroth drive controller
Fig. 6-3:
Power connection via connector socket, connection diagram
●
Observe the necessary power wire cross section within the
project planning manual
MAD/MAF to connect the motors.
●
Use ready-made connection cables of Rexroth. See docu‐
mentation
4
3
A
A
U
M
B
B
V
3
C
C
W
D
D
5
PTC
1TP1 (+)
E
E
1TP2 (-)
H
H
BD (+)
F
F
BD (-)
G
G
6
7
L
Asynchronous Housing Motors
Rexroth Connection Cables.
R911336186_Edition 02 Bosch Rexroth AG
23/57
Assembly
1
D
F
H
G
E
A
C
K
J
B
L
2
D
H
F
G
E
A
C
K
J
B
L