Safety Instructions; About This Product; Intended Use; Unintended Use - Bosch Rexroth MAD100 Operating Instructions Manual

Asynchronous housing motors
Hide thumbs Also See for Rexroth MAD100:
Table of Contents

Advertisement

MAD / MAF Asynchronous Housing Motors
2

Safety instructions

2.1

About this product

2.2

Intended use

2.3

Unintended use

2.4

Qualification of personnel

Observe the general safety notes in this chapter and the safety instructions in
this documentation. Therewith, you avoid personal danger, damage and er‐
rors.
This operating instruction must be stored and transferred in case
of sale during the complete product lifetime.
Prerequisites for proper and safe use of the motors are proper transport, ap‐
propriate storage, proper assembly and connection, careful maintenance, op‐
eration and overhaul.
The motors have been designed for installation in industrial machinery. The
motors are according to the following standards and directives.
Standards
EN 60034-1
Rating and performance behavior
EN 60034-5
Type of protection
Directives
2006/95/EG
Low voltage directive
The machine manufacturer must evaluate the electric and mechanic safety
as well as environmental influences in the assembled state of the machine
according to the Machine Directive 2006/42/EC and DIN EN 60204-1 (safety
of machines).
The electric installation must comply with the protection requirements of the
EMC Directive 2004/108/EC. The plant manufacturer is responsible for ap‐
propriate installation (for example: physical separation of signal and power
cables, using shielded cables, ...). The EMC instructions of the converter
manufacturer must be observed.
Start-up is prohibited as long as the conformity with these directives is de‐
clared.
Any use of the MAD/MAF motors outside of the specified fields of application
or under operating conditions and technical data other than those specified in
this documentation is considered to be "inappropriate use".
Unless explicitly provided for this purpose, the motors may not be used in ex‐
plosion-hazardous areas (ATEX).
Direct operation on the three-phase network is forbidden.
For the purpose of this manual, qualified personnel means persons who are
familiar with transporting, installing, mounting, commissioning and operating
the components of the electrical drive and control system and the associated
hazards and have an appropriate qualification for their job.
Safety instructions
R911336186_Edition 02 Bosch Rexroth AG
3/57

Advertisement

Table of Contents
loading

Table of Contents