Mains power
Power consumption
Auxiliary voltage
Motor fuse F1
Control fuse F2
Recommended max. door weight
Ambient temperature
Dimensions:
PowerSwing
PowerSwing-2
To be installed internally or externally with suitable weather protection.
* 716 is the European short header package.
746 allows for the operator to be mounted to the adapter plate with the addition of 2 cover
clips.
6
© Copyright 2006 Besam Entrance Solutions. May not be reprinted or reproduced without permission.
Technical Specifi cations
120 V AC ± 10 %, 60 Hz
fuse 10 A
Note!
Switch with clearly marked off-position, having a
contact separation of at least 3 (1/8'') mm in all
poles, must be incorporated in the fi xed wiring.
The operator can also be plug-connected to a
wall socket.
max. 230 W
13- 20 V DC, 275 mA
24 V DC, 375 mA (stabilized)
10 Amp (10 ATH)
1/2 Amp (500 mAT)
Arm system PUSH
250 kg (550 lb) for door leaf width 1600 mm (63'')
Arm system PULL
100 kg (220 lb) for door leaf width 1400 mm
(55''). Higher door weights on request.
The PowerSwing complies with the door
weights/widths stated in the:
Controlled door closing,
EN 1154 sizes 3-6
Electrically powered hold-open device for
swing doors,
EN 1155
Coordination unit for rebated doors, EN 1158
Türschliesser mit Öffnungsautomatik
(Drechfl ügelantrieb)
DIN 18263-4 AU Grösse 3-6
ANSI/BHMA A156.10, A156.19
UL325/CUL325
SITAC 0166/99
-30°C to +50°C (-22°F to 122°F)
Length:
716 mm, 746-1600 mm *
(28-3/16", 29-17/32" – 63'')
Length:
1435-3200 mm
(56 1/2" – 126")
Height:
110 mm (4-11/32")
Depth:
110 mm (4-11/32")