Tools required
Installation on double doors
Note:
PowerSwing US23-0922-02
© Copyright 2006 Besam Entrance Solutions. May not be reprinted or reproduced without permission.
This instruction comprises the installation of the Besam PowerSwing with arm
systems PUSH which push the door open and PULL which pull the door open.
Always make sure, before commencing the installation, that the door leaf and the
wall are properly reinforced at the attachment points.
Base material
Steel
Aluminium
Reinforced concrete
Wood
Brick wall
See also "Installation examples" page 37.
*Thin-wall profi les must be reinforced with rivnuts
Torx T8, T10, T20 and T25
Metric hexagonal key 3, 4 and 6 mm.
Flatblade screwdriver, small
Torque wrench with metric Allen socket 6 mm.
If the operators are to be mounted at the same height with pushing and pulling arm
systems, the height is deter mined by the pulling arm system, PULL. The pushing
arm system PUSH must always have a shaft extension, minimum 50 mm (2"),
maximum 70 mm (2 3/4") to match the mounting heights visually.
Example: if PULL has a 20 mm (3/4") extension, the PUSH must have a 70 mm
(2 3/4") extension. If PULL has 0 mm extension, the PUSH must have a 50 mm
(2") extension.
For installation follow the instructions for the applicable arm system.
The short operator package requires the installer to follow the "Mounting
Plate Applications" installation procedure. For jamb to jamb applications
(full length header box surface applied) the installer must use "Adapter Plate
Application".
10-21-2002

Mechanical Installation

Minimum requirements
5 mm (3/16")*
6 mm (1/4")*
min. 50 mm (2") from the underside
50 mm (2")
Expansion-shell bolt, min. M6x85, UPAT PSEA
B10/25 min. 50 mm (2") from the underside