Emerson Micro Motion 1600 Installation Manual page 20

Table of Contents

Advertisement

Wiring the channels
March 2022
Figure 4-5: Internally-powered FO: output amplitude versus load resistance [24 VDC
(Nom) open circuit]
A. Output amplitude (V)
B. Load resistor (Ω)
Figure 4-6: Externally-powered FO wiring
A
A. Frequency Output
B. Channel B
C. 5–30 VDC (maximum)
D. 500 mA current (maximum)
E. Counter
4.2.4
Wire the Discrete Output
Wire the Discrete Output in nonhazardous installations.
Prerequisites
Meter installation and wiring should be performed only by suitably-trained personnel
using the appropriate government and corporate safety standards.
Procedure
Wire to the appropriate output terminal and pins.
20
24
22
20
18
16
14
A
12
10
8
6
4
2
0
0
B
WARNING
250
500
750
B
Micro Motion 1600 Ethernet Transmitters
Installation Manual
00825-0100-1600
1000
C
D
E

Advertisement

Table of Contents
loading

Table of Contents