Installation; Usb Test Ports; Software Installation - LeCroy USB Mobile HS User Manual

Protocol analyzer
Table of Contents

Advertisement

USBMobileHS User Manual
Chapter 3: Installation

3.1 USB Test Ports

Connect a host to one of the mini A-B receptacles (use an adaptor if necessary), and
connect your device to the other. It does not matter which receptacle you plug into.
Note:

3.2 Software Installation

Step 1 Insert the USBMobileHS CD-ROM into your computer.
Step 2 Click Install Software when the Auto-Run program is displayed.
Step 3 Follow the installation instructions on your screen.
The Install Wizard automatically installs the necessary files to the computer's hard drive.
The software is installed in the C:\Program Files\LeCroy\USBMobileHS directory
unless you specify otherwise. Follow the installation instructions on your screen.
LeCroy Corporation
The USBMobileHS USB 2.0 Classic Analyzer is not a hub device; it connects
to a USB branch by inserting a non-intrusive, high impedance tap. Because
of the poor signal quality in the middle of a USB cable, LeCroy recommends
using the shortest possible cables so that the total length of both cables
together is less than 6 feet. The USB cables provided with your Analyzer
meet this requirement. When longer cables are used, the Analyzer might
record incorrect data.
Chapter 3: Installation
11