Connecting Counters To Events - LeCroy USB Mobile HS User Manual

Protocol analyzer
Table of Contents

Advertisement

Chapter 10: Recording Options

10.6 Connecting Counters to Events

The right side of the Actions window contains two Counter buttons marked Count1 and
Count2.
These counters provide a way of triggering after a number of events have passed, such
as "Trigger after the 20th IN packet."
When an event is linked to a counter, the counter appears under that event on the left
side of the Actions window. Counters have blue dots in their top left corner that provide
access to pop-up menus. The menus provide the means of setting the counter value. The
counter can be set between 1 and 65,535.
To connect an event to a counter:
Step 1 Open the Event window and select an Event.
Step 2 Open the Actions window.
Step 3 Click the Event button.
Step 4 Click one of the two counters.
120
An Event button appears in the Actions window.
The window displays an Event button that is connected to the Trigger button on
the right via a line.
An arrow connects the Event button to the mouse pointer.
The Event automatically connects to the Counter button and then connects to the
Trigger button.
USBMobileHS User Manual