Panel (control and display panel)

The CDP 312 control and display panel communicates
with the power converter via a serial connection in
accordance with the RS 485 standard at a transmission
rate of 9.6 kBaud. It is an option for the converter unit.
After completion of commissioning, the panel is not
necessarily required for diagnostic. The basic unit has a
7-segment display indicating errors.
For selecting and adjusting
all parameters and signals.
0 L
Group
17 RAMP GENERATOR
and name
Subgroup
08 ACCEL 1
and name
20.0 s
Value
Selects the display of feedback values plus the
signal group and the error memory group.
ID number
Control
Speed
of the
location
reference
L = local
rpm
drive
selected
= remote
0 L
Status row
SPEEED ACT
Actual signal
name and value
CONV CUR
U ARM ACT
Cursor shows
the row selected
are used to change the group. In the parameter and
reference presetting modes, you can alter the param-
eter value or the reference setting ten times faster by
means of the twin arrow keys than by means of the
is used to select local (control
panel) or remote control.
1 = last fault
0 L
2 = last-but-one fault
1 LAST FAULT
99 = last fault
Name of Fault
Emergency stop
or alarm
3212:59:35:56
Total time after
switch-on
HHHH:MM:SS.ss
in local mode switches the main contactor on.
Parameters
0,0 rpm
00
Actual
Run status
Main contactor
status
1 = Run
0 = open
0 = Stop
1 = closed
0,0 rpm
00
0,0 rpm
0 A
0 V
Twin arrow keys
single arrow key.
Local/Remote
Reset
Fault acknowledge key.
0,0 rpm
00
On
Fig. 2.5/8: Function keys and various displays on the removable
control and display panel.
II F 2-14
3ADW000072R0501_DCS600_System_description_e_e
Features
• 16 membrane pushbuttons in three function groups
• LCD display has four lines with 20 characters each
• Language: English
• Options for the CDP 312:
– cable, separated from the power converter for
utilization; 3 m long
– kit for mounting the panel in the switchgear
cubicle door
Function
Selects the "functions" operating mode; can be used
to perform special functions such as uploading and
downloading of parameter sets.
0 L
Status row
UPLOAD
Functions to be
selected
DOWNLOAD
Display contrast
CONTRAST
setting
Drive
for extensions
Enter
is used in the following modes:
Parameter setting:
enter new parameter value
Actual value
signal display:
enter the current signal selec-
tion mode
Signal selection:
accept selection and return to
the feedback value signal dis-
play mode
Arrow keys
are used to select parameters within a group. You al-
ter the parameter value or the reference setting in
the parameter and reference presetting modes. In
the feedback signal display mode, you select the line
you want.
Start
starts the drive in local mode.
Stop
shuts the drive down if you are in local mode.
Reference
is used to activate the reference presetting mode.
Off
in local mode switches the main contactor off.