Serial Interfaces; Operation By The Panel - ABB DCS 600 MultiDrive Manual

Hide thumbs Also See for DCS 600 MultiDrive:
Table of Contents

Advertisement

Serial interfaces

There are various serial interface options available for
operation, commissioning, diagnosis and controlling.
For the control and display panel CDP 312 are serial
connections X33:/X34: on the SDCS-CON-2 availa-
ble. Three additional serial interfaces are available on
the SDCS-AMC-DC 2 board.
These interfaces use plastic or HCS optical fibres.
Channel 3 is used for drive/PC interfacing. Channel 0
for fieldbus module interfacing or communication to
the overriding control system. Channel 2 is used for
Master-Follower link or for I/O extension. All three
serial interfaces are independent from each other.
Remark:
Fieldbus modules Nxxx
(CH0) require the
SDCS-AMC-DC Classic 2
board - all others (FCI,
AC80...) require the
SDCS-AMC-DC 2 board.
Operation by panel
Panel location
There are different possibilities for mounting the panel:
• On the converter module.
• With MultiDrive door mounting kit.
Power supply
PE
SH
SHF
DG
D(N) D(P)
X2
RXD
Nxxx-01
Nxxx
T XD
xxxxxxxx
ADAPTER
XM IT
BUS
T ERM INAT ION
REC
ON
OF F
X1
ERRO R
PE
+24V
0V
SH
SHF
DG
D(N) D(P)
to the PLC
FCI
AC80
AC800M
- Master-Follower link
Control
Fig. 2.5/5: Options for serial communication
3ADW000072R0501_DCS600_System_description_e_e
Different SDCS-AMC 2 boards are available to adapt
optical cables, cable length and serial interfaces. The
different SDCS-AMC 2 boards are equipped with 10
or 5 Mbaud optical transmitter and receiver devices.
A few basic rules must be considered:
• Never connect 5 Mbaud and 10 Mbaud devices.
• 5 Mbaud can handle only plastic fibre optic.
• 10 Mbaud can handle plastic or HCS cable.
• The branching unit NDBU 95 extends the maxi-
mum distance.
• The maximum distance and suitable configuration
can be found in the manual Configuration Instruc-
tions NDBU 85/95; Doc no.: 3ADW000100.
SDCS-CON-2
X16:
LED Monitoring Display
If the MultiDrive door Mounting kit is used it is
possible to insert up to three LED monitoring displays
for indicating status as run, ready and fault and a
selectable parameter indicator (0...150%) per drive.
The display is connected to the SDCS-CON-2 board
(X33:/X34:) or to the panel socket NDPI through a
universal Modbus link.
R
R
F
D
U
L
0
50
1
Y
N
T
Fig. 2.5/6: LED Monitoring Display
SDCS-CON-2
X33:/
X34:
R
R
F
D
U
L
0
1
Y
N
T
CDP 312
SDCS-CON-2
X33:/
X34:
R
R
F
D
U
L
0
1
Y
N
T
Fig. 2.5/7: Connection of the LED Monitoring Display
electrical
X33:
connection
X34:
≤ 3 m
Interface
Operation
100
150
NLMD
50
100
150
NLMD
50
100
150
II F 2-13
CDP 312
Dcs6_com1b.dsf
PC

Advertisement

Table of Contents
loading

Table of Contents