14 TROUBLESHOOTING
Below is a list of faults and malfunctions which could arise while using the machine.
For all problems not included in this table, contact technical assistance.
PROBLEM
The boiler fill level display
flashes
No water is delivered from
the group
EN
The water does not heat up
Continuous water fill (the
water level flashes on the
display)
The doses delivered are
not regular
The steam wand leaks with
the tap closed
Steam leaks from under the
tap knob when open
Insufficient coffee is used
Troubleshooting
CAUSES
The mains water or purifying
filter taps are closed
Boiler fill malfunction
The mains water or purifying
filter taps are closed
The filter on the water intake
coupling is clogged
Clogged gigleur
Heating element burnt out
Temperature sensor
malfunction
Faulty level sensor
Faulty volumetric doser
Faulty gasket
Faulty tap spindle seal
The ground coffee is too fine
or too coarse
Shower screen and filters
partially clogged
110
REMEDY
Open the tap
Turn off power for at least 5
seconds, then turn on again
by pressing the switch.
Call technical assistance
Open the tap
Remove and clean
Check regeneration of the
water purifying filter
Call technical assistance
Call technical assistance
Call technical assistance
Call technical assistance
Call technical assistance
Call technical assistance
Call technical assistance
Check grinding time and/or
adjust grinding coarseness