Advertisement

3.2.3.1 MINIMUM POSITION (Lo)

The minimum position parameter is the minimum
opening which may be reached in auto mode. The
curtain will not close beyond this value. Range: CLo,
1 ... 99. This parameter is not available when DIP
switch #4 is set to SVC mode.

3.2.3.2 MAXIMUM POSITION (Hi)

The maximum position parameter is the maximum
opening which may be reached in auto mode. The
curtain will not open beyond this value. Range:
Lo+1 , ... 99,Open
3.2.3.3 PROBE READING (Prb)
The Probe parameter displays the temperature read by
the probe. The current value can either be in °C or °F,
depending on the units set by the master control (SVC,
IC).

3.2.3.4 CALIBRATION (CAL)

The Calibration parameter can be activated or
deactivated when the flashing message "CAL" is
displayed and both
simultaneously. When a calibration
progress, it may be interrupted by pressing the
button simultaneously. If for any reason calibration is
interrupted, the module will safely resume its operation
with preceding values.
www.monitrol.com
CHAPTER 3 - USER'S GUIDE
and
buttons are pushed
cycle is in
and
Page 23