Page 2
CPS-3M Although the manufacturer has made every effort to ensure the accuracy of the information contained herein, this document is subject to change without notice due to ongoing product development. WARNING AND PRECAUTIONS Equipment, probe failure, blown fuses and/or tripped breakers may prove harmful to the contents of the building.
TABLE OF CONTENTS CHAPTER 1 - INTRODUCTION General ................5 Description ...............5 Definition of terms .................6 CHAPTER 2 - INSTALLATION Unpacking ................7 Installation ...............7 Switch Settings ..............8 2.3.1 Line Voltage Selector Switch ...........8 2.3.2 Software Setting DIP Switch ..........8 Connection Procedure .............9 2.4.1 Input Power ..............9 2.4.1.1 115 VAC ................9...
Page 4
CPS-3M Zone 1 Record Low Temperature ........24 Zone 1 Record High Temperature .........25 Zone 1 Max Run Time .............26 Zone 1 Main Set PointTemperature ........27 Zone 1 Room Temperature Display ........28 FUNCTION 2 Zone 2 Differential ............29 Zone 2 Delay Timer (actuator 2) ........30 Zone 2 High Temperature Alarm ........31...
Moreover, the CPS-3M is equiped with state of the art logic for extra-accurate ventilation and heating control. The present manual has been published in order to make custom installation and control easier.
CPS-3M DEFINITION OF TERMS TEMPERATURE MAIN SET POINT The desired temperature in a room. ROOM TEMPERATURE The actual room temperature AIR INLET/ CURTAIN A device which regulates airflow into a building by controlling the opening or closing of an air passage.
Failure to do so may void the warranty! 2.1 UNPACKING Unpack the CPS-3M from its box and inspect contents for damage. Should the contents appear to be damaged, contact your local distributor to return the material .
The CPS-3M is configured for a variety of options via the two following switches: 2.3.1 - Line Voltage Selector Switch This switch is located on the surface of the main (bottom) board and adapts the CPS-3M to 115 VAC or 230 VAC line voltage. 230V 115V See figure 1 2.3.2 - Software setting switch...
2.4.1 - Input power Use a screwdriver to remove cable knock-outs for the installation of cables on the CPS-3M. Do not power up the CPS-3M until all connections have been completed! 2.4.1.1 - 115 VAC Make sure that the line voltage selector switch is set to 115 VAC.
These cables can measure up to 500 feet (150 meters). Probes longer than 10 feet (3 meters) must be shielded with a #18AWG aluminum wire, or one bigger. The shield must be connected to the CPS-3M’s SHLD terminal. The connections for 2 temperature probes are illustrated in figure 2, whereas the connections for temperature averaging are illustrated in figure 3.
Make the normally closed (NC) or normally open (NO) connections as indicated in figure 2. Momentary power interruptions may trigger false alarms! To avoid them, when the CPS-3M is connected to an alarm system, install a time delay relay between the CPS-3M and the alarm system.
Page 12
CPS-3M Figure 1 Wiring for 2 actuators and 1 heating unit WARNING!!! SET LINE VOLTAGE TO CORRECT VALUE BEFORE ATTEMPTING TO OPERATE THE CONTROL. Figure 1a Wiring diagram for a three phase motor Page 12 www.monitrol.com...
CHAPTER 2 - INSTALLATION Figure 2 Temperature probes Figure 3 Probe connection for temperature averaging in 1 zone Page 13 www.monitrol.com...
Page 14
CPS-3M Figure 4 Main (bottom) board: terminal blocks, switch and jumpers. Figure 5 Four wire motor with parallel windings Page 14 www.monitrol.com...
Control Dials The center dial is the selector dial and is used to select one of the CPS-3M’s 12 primary or 8 secondary functions. The dial to the right of the selector dial is the adjustor dial and is used to adjust the setting of each function or to enter secondary mode.
Page 16
(12) to any other secondary function. When secondary functions (2) through (11) are selected, the status window displays a blinking value along with a scrolling LED display. Selection of function (12) switches the CPS-3M back to primary mode. Page 16 www.monitrol.com...
If temperature is lower than 42.0°F, Lo is displayed. If temperature is higher than 111°F, Hi is displayed. Viewing the room temperature: • rotate the selector dial to position (1) The room temperature for zone 2 is displayed on the CPS-3M. Page 17 www.monitrol.com...
CPS-3M ZONE 2 MAIN SET POINT TEMPERATURE (MANUAL MODE) main point establishes target temperature in the building. The main set point temperature is adjusted in 0.5 degree increments from a minimum setting of 42.0°F (5.5°C) to a maximum setting of 111°F (44.0°C).
• rotate the selector dial to position (3), • rotate the adjustor dial counterclockwise to decrease the setting, and clockwise to increase The CPS-3M automatically calculates a run time according to temperature variations and the difference between room temperature and the main set point.
Viewing the highest temperature recorded in zone 2: • rotate the selector dial to position (4) Clearing the high temperature value: • quickly rotate adjustor dial counterclockwise, then clockwise. CLr will be briefly displayed on the CPS-3M Page 20 www.monitrol.com...
Lo is displayed. Viewing the lowest temperature recorded: • rotate the selector dial to position (5) Clearing the low temperature value: • Quickly rotate adjustor dial counterclockwise, then clockwise. CLr will be briefly displayed on the CPS-3M. Page 21 www.monitrol.com...
CPS-3M HEATING SET POINT The CPS-3M has an absolute heating set point; meaning that this function establishes the temperature at which heating goes ON. It stops, then starts again when temperature reaches the heating differential set by position (7). When 2 zones are selected, the temperature considered is the average temperature of the 2 zones.
Adjusting the heating differential: • rotate the selector dial to position (7), • rotate the adjustor dial counterclockwise to decrease the differential, and clockwise to increase it. The differential is displayed on the CPS-3M. Page 23 www.monitrol.com...
Viewing the lowest temperature recorded in zone 1: • rotate the selector dial to position (8) Clearing the low temperature value: • quickly rotate adjustor dial counterclockwise, then clockwise. CLr will be briefly displayed on the CPS-3M. Page 24 www.monitrol.com...
Viewing the highest temperature recorded in zone 1: • rotate the selector dial to position (9) Clearing the high temperature value: • quickly rotate adjustor dial counterclockwise, then clockwise. CLr will be briefly displayed on the CPS-3M. Page 25 www.monitrol.com...
• rotate the adjustor dial counterclockwise to decrease the setting, and clockwise to increase The timer’s setting is displayed on the CPS The CPS-3M automatically calculates a run time according to temperature variations and the difference between room temperature and the main set point.
• rotate the adjustor dial counterclockwise to decrease the setting, and clockwise to increase The main set point temperature is displayed on the CPS-3M. Manual mode: The actuator motor may be manually controlled by adjusting the main set point to OPN or CLO, thereby causing the air inlet to either remain fully open or closed.
C). If temperature is lower than 42.0°F, Lo is displayed. If temperature is higher than 111°F, Hi is displayed. Viewing the room temperature: • rotate the selector dial to position (12) The room temperature for zone 1 is displayed on the CPS-3M. Page 28 www.monitrol.com...
This feature, which greatly reduces equipment wear, represents the inactivity zone for the CPS-3M, that is if the main set point is DIFF reached. The differential is adjusted in 0.5 degree increments from a minimum setting of 0.0°F...
• rotate the adjustor dial counterclockwise to decrease the delay, and clockwise to increase it. The delay timer is displayed on the CPS-3M. Example: The delay timer is set to 1 minute. The actuator motor, when called upon to open the air inlet, will operate after a delay of 1 minute.
• rotate the selector dial to position (4), • rotate the adjustor dial counterclockwise to decrease the setting, and clockwise to increase The high temperature relative alarm setting is displayed on the CPS-3M. Page 31 www.monitrol.com...
• rotate the selector dial to position (5), • rotate the adjustor dial counterclockwise to decrease the setting, and clockwise to increase The low temperature relative alarm setting for zone 2 is displayed on the CPS-3M. Page 32 www.monitrol.com...
• rotate the selector dial to position (8), • rotate the adjustor dial counterclockwise to decrease the setting, and clockwise to increase The low temperature relative alarm setting for zone 1 is displayed on the CPS-3M. Page 33 www.monitrol.com...
• rotate the selector dial to position (9), • rotate the adjustor dial counterclockwise to decrease the setting, and clockwise to increase it. The high temperature relative alarm setting is displayed on the CPS-3M. Page 34 www.monitrol.com...
• rotate the adjustor dial counterclockwise to decrease the delay, and clockwise to increase it. The delay timer is displayed on the CPS-3M. Example: The delay timer is set to 1 minute. The actuator motor, when called upon to open the air inlet, will operate after a delay of 1 minute.
This feature, which greatly reduces equipment wear, represents the inactivity zone for the CPS-3M, that is if the main set point is DIFF reached. The differential is adjusted in 0.5 degree increments from a minimum setting of 0.0°F...
− Display is Make sure the line voltage selector switch blank is properly set. − Make sure the 10 pin flat cable, between the main board and the CPS-3M faceplate, is properly connected. Page 40 www.monitrol.com...
CPS-3M RECORD FORM FUNCTION 1 Dial Option Default Setting User Temperature set point #2 5.5 to 44°C 42 to 111°F Actuator max. run time 1 sec. to 4 min. Heating set point 5.5 to 45.0°C 41 to 112°F Heating differential 0.0 to 3.0°C...
WARRANTY Limited Warranty manufacturered equipment supplied components have gone through rigorous inspection to assure optimal quality of product and reliability. Individual controls are factory tested under load, however the possibility of equipment failure and/or malfunction may still exist. For service, contact your local retailer or supplier. The warranty period shall be for two years from manufacturing date.
Page 44
MAV CPS-3M Ver: 03 April 2004 www.monitrol.com...