Input Matrix

Examples of wiring to take ON/OFF status of 24 switches by using MTR instructions are given below.
For the instructions, refer to
Programming examples
SM400
MTR
X010 Y010 M30
Wiring examples
• Sink wiring
The example is the wiring for the input/output of the FX5UC-32MT/D.
Fuse
When the input
points X000 to
X017 are used,
connect a pull-up
resistor (3.3 kΩ/
0.5 W).
FX5UC-32MT/D
• Source wiring
The example is the wiring for the input/output of the FX5UC-32MT/DSS.
Fuse
When the input
points X000 to
X017 are used,
connect a pull-
down resistor
(3.3 kΩ/0.5 W).
FX5UC-32MT/DSS
*1 The grounding resistance should be 100 Ω or less.
MELSEC iQ-F FX5 Programming Manual (Instructions, Standard Functions/Function Blocks).
K3
0.1 A 50 V
diode is
necessary.
24 V DC
Class D
*1
grounding
COM X010 X011 X012 X013 X014 X015 X016 X017
COM0 COM0 Y010 Y011 Y012 Y013 Y014 Y015 Y016 Y017
0.1 A 50 V
diode is
necessary.
24 V DC
Class D
*1
grounding
COM0 X010 X011 X012 X013 X014 X015 X016 X017
+V0 +V0
X011
X013
X015
X017
X012
X014
X016
X011
X013
X015
X017
X012
X014
X016
Sink input
Transistor output (sink)
X011
X013
X015
X017
X012
X014
X016
X011
X013
X015
X017
X012
X014
X016
Source input
Transistor output (source)
Y010 Y011 Y012 Y013 Y014 Y015 Y016 Y017
6