CC-Link remote I/O
Remote I/O points that are used in FX3U-16CCL-M are calculated as "number of stations X 32
points". Even if using less than 32 remote I/O points, calculate as "number of stations X 32 points".
Maximum number of
CC-Link remote I/O
points
256 points
In the FX5UC CPU module, FX3U-16CCL-M parameters are set up by PLC program and will occupy up to 256 remote
I/O points.
When the total number of the number of input/output points (including occupied input/output points) and the number of remote
I/O points of FX3U-128ASL-M that is connected to the left side exceeds 256 points, the difference of 512 minus that total can
be used as CC-Link remote I/O points.
AnyWireASLINK remote I/O
The number of input/output points set by the rotary switch of the AnyWireASLINK master is assigned as remote I/O
of AnyWireASLINK.
Use the number of input/output points set by the rotary switch of the AnyWireASLINK master as the number of remote
I/O points.
For details, refer to FX3U-128ASL-M USER'S MANUAL.
Maximum number of AnyWire
ASLINK remote I/O points
128 points
4 SYSTEM CONFIGURATION
40
4.3 Limitation on the Number of Input/Output Points
Actually used CC-Link remote I/O points
(a)
=
(a) CC-Link remote
I/O points
AnyWireASLINK remote I/O
(b)
(b) Number of remote I/O points assigned to
AnyWireASLINK master
×
32 points
stations
The total number of
remote I/O stations × 32 points
points