Table 5.1 Auditable Events - Konica Minolta BIZHUB 920 Software Manual

Security target
Hide thumbs Also See for BIZHUB 920:
Table of Contents

Advertisement

FAU_GEN.1
Hierarchical to: No other components.
FAU_GEN.1.1
The TSF shall be able to generate an audit record of the following auditable events:
a) Start-up and shutdown of the audit functions;
b) All auditable events for the [selection: minimum, basic, detailed, not
specified] level of audit; and
c) [assignment: other specifically defined auditable events].
[selection: minimum, basic, detailed, not specified]
- Not specified
[assignment: other specifically defined auditable events]
- Table 5.1 shows the events targeted to audit.
Functional component
FIA_UID.2
FIA_UAU.2
FIA_AFL.1
FIA_SOS.1[1]
FIA_SOS.1[2]
FDP_SOS.1
FDP_ACF.1[1]
FDP_ACF.1[2]
FMT_SMF.1
FDP_MTD.1
Copyright© 2005 KONICA MINOLTA BUSINESS TECHNOLOGIES, INC., All Rights Reserved
Audit data generation

Table 5.1 Auditable Events

Success and failure of identification in identifying of administrator,
CE, general user who owns User BOX
Success and failure of identification in identifying of administrator,
CE, general user who owns User BOX
Attainment to the threshold value of unsuccessful authentication of
administrator, CE, general user who owns User BOX
Acceptance of the tested authentication information
Acceptance of the tested authentication information
Acceptance of the tested authentication information
Request of success in executing of the operation for the object
Request of success in executing of the operation for the object
Use of management function
Success of the value of administrator data
34
Audit information

Advertisement

Table of Contents
loading