Follow the manual damage prior to every use of the device. Do not use any Information marked with this symbol indicates that the defective devices or device parts. instructions must be observed. spot cooling air conditioning unit PT 3500 SP...
Page 3
(e.g. open flames, an active gas appliance or an electric heater). • Please note that the refrigerant is odourless. • Only install the device in compliance with the national installation regulations. spot cooling air conditioning unit PT 3500 SP...
Page 4
Remove the condensation tank and empty it. Make sure that the condensation tank is inserted correctly before switching the device back on. Follow the manual This symbol indicates that the operating manual must be observed. spot cooling air conditioning unit PT 3500 SP...
Page 5
Do not leave the packaging lying around. Children may use it as a dangerous toy. Warning Risk of death due to suspended loads! Make sure that nobody is situated in the immediate proximity. spot cooling air conditioning unit PT 3500 SP...
Device depiction Designation Hot air duct Transport handle Condensation tank Wheels with parking brake Control panel Condensation hose connection Cable storage compartment with power cable Air inlet with air filter Cold air duct spot cooling air conditioning unit PT 3500 SP...
• Store the device in an upright position where it is protected refrigerant cannot accumulate. from dust and direct sunlight. • If required, use a cover to protect the device from invasive dust. spot cooling air conditioning unit PT 3500 SP...
Page 8
Operating the device with a condensation drain hose is also possible. Connecting the hot air duct The hot air duct (1) must be connected to the device before use. 1. Screw the hot air duct (1) onto the device. spot cooling air conditioning unit PT 3500 SP...
Page 9
Without the air filter, the inside of the device will be heavily contaminated. This could reduce the Indoors Outdoors performance and result in damage to the device. Make sure that the air filter (8) is installed before switching the device on. Machine spot cooling air conditioning unit PT 3500 SP...
Is lit when the Spot cooling mode is ð The room air cooling LED (23) will be illuminated to mode LED activated indicate cooling mode. Room air cooling Is lit when the Room air cooling mode is activated spot cooling air conditioning unit PT 3500 SP...
Page 11
The function can be set in all operating modes. The timer has two modes of operation: • automatic switch-on upon expiry of a preset number of hours • automatic switch-off upon expiry of a preset number of hours spot cooling air conditioning unit PT 3500 SP...
The device is loud or vibrates: • Check whether the device is set up in a stable and upright position. Condensate is leaking from the basic device: • Check the device for leaks. spot cooling air conditioning unit PT 3500 SP...
Page 13
(Pipe Sensor) (Pipe Sensor) Malfunction of the Replacing the sensor for the sensor for the sensor line of the sensor line of the vaporizer (Out Air vaporizer (Out Air Sensor) Sensor) spot cooling air conditioning unit PT 3500 SP...
Page 15
Protect electrical components from moisture. Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth. spot cooling air conditioning unit PT 3500 SP...
Page 16
If you want to continue using the device: • Reconnect the device to the mains. If you do not intend to use the device for a considerable time: • Store the device according to the Transport and storage chapter. spot cooling air conditioning unit PT 3500 SP...
Condensation tank capacity Dimensions (length x width x 430 x 493 x 944 mm height) Minimum distance to walls and other objects: top: 90 cm sides: 30 cm front: 30 cm rear: 30 cm Weight 49 kg spot cooling air conditioning unit PT 3500 SP...
Page 18
Circuit diagram MOTOR CAPACITOR H-FAN L-FAN COMP AC-L COMPRESSOR COMP. TRANSFORMER CAPACITOR RD R 35uF Water level ICE-T ROOM-T OUT-T DISP Display Panel YE / GN spot cooling air conditioning unit PT 3500 SP...
Page 19
Overview and list of spare parts Note: The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual. spot cooling air conditioning unit PT 3500 SP...
Page 20
Base plate Electric control box cover plate Screw liner Universal casters with break Wire clip Control panel cover Universal casters Cable 0 coil Water tank support plate Compressor ass. 0 coil Water tray spot cooling air conditioning unit PT 3500 SP...
The icon with the crossed-out waste bin on waste electrical or electronic equipment stipulates that this equipment We – Trotec GmbH – declare in sole responsibility that the must not be disposed of with the household waste at the end of product designated below was developed, constructed and its life.
Need help?
Do you have a question about the PT 3500 SP and is the answer not in the manual?