Improper use Do not place the air conditioner PAC 2000 E on moist or wet ground. Do not use the device outdoors. Do not place any objects, e.g. clothing, on the device.
Lower air inlet Hose connection for drip protection Exhaust air hose connection Upper air inlet with air filter B Mains power cable with holding fixture Compartment for remote control Remote control Operating manual – Local air conditioner PAC 2000 E...
1. Connect the individual hose components until their tight fit is ensured. 2. Put the adapter (13) from above onto the exhaust air connection (7) at the device. – The adapter (13) snaps into place. Operating manual – Local air conditioner PAC 2000 E...
Page 6
3. Attach the sealed condensation hose to the condensate outlet (see fig. C). 4. Affix the condensation hose by means of the hose clip and snap it into the retaining clip (see fig. C). Operating manual – Local air conditioner PAC 2000 E...
3. Select the desired operation mode by pressing the MODE button (23). Setting the operating mode • Press the MODE button (23) to switch between the operating modes. – COOLING (COOL) – DEHUMDIFICATION (DRY) – VENTILATION (FAN) Operating manual – Local air conditioner PAC 2000 E...
Page 8
40 Timer setting indication Flashes during timer setting. 41 Temperature/hour Indicates the target temperature or the indication select number of hours in timer operation. 42 Operating mode indication Indicates the selected operating mode. (MODE) Operating manual – Local air conditioner PAC 2000 E...
Your device still does not operate correctly after these • Have an electrical inspection carried out by Trotec. checks? Bring the device to a specialist company for cooling and air-conditioning or to Trotec for repair. Operating manual – Local air conditioner PAC 2000 E...
Page 10
• Voltage at the mainboard is higher than the Contact Trotec overvoltage protection value ON/OFF • The inside of the device is heavily contaminated Contact Trotec button (32) lights Remove any foreign objects and dirt from the up briefly five Overvoltage protection air inlet and outlet.
Page 11
Error code Display Fault Cause Remedy • The inside of the device is heavily contaminated Contact Trotec Remove any foreign objects and dirt from the air inlet and outlet. • Air inlet or air outlet is blocked Observe the minimum distances specified in the technical data •...
Cleaning the housing Clean the device with a soft, damp and lint-free cloth. Ensure that no moisture enters the housing. Do not use abrasive cleaners. Operating manual – Local air conditioner PAC 2000 E...
Before reinserting the air filter, make sure that it is undamaged and dry! • Reinsert the cleaned, dry filters in the device in reverse order. Technical annex Wiring diagram Operating manual – Local air conditioner PAC 2000 E...
Page 14
Exploded assembly drawing Note! The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual. Operating manual – Local air conditioner PAC 2000 E...
Page 15
Further information is provided on the nameplate. Dispose of the refrigerant appropriately and according to the national regulations. Operating manual – Local air conditioner PAC 2000 E...
Page 16
Produktdatenblatt / Product Fiche Lokales Klimagerät / Local Air Conditioner PAC 2000 E 1210002004 Artikel-Nr. / Item-No. nur Kühlung / Cooling only Funktion dB(A) re 1 pW Schallleistungspegel / Sound Power Level Kältemittel / Refrigerant R 410 A Typ / Type Gewicht / Weight 2.088...
Page 18
Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info @ trotec.com www.trotec.com...