Advertisement

Quick Links

PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S
EN
ORIGINAL INSTRUCTIONS
AIR CONDITIONER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec PT 4500 S

  • Page 1 PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S ORIGINAL INSTRUCTIONS AIR CONDITIONER...
  • Page 2: Table Of Contents

    Info Information marked with this symbol helps you to carry out your tasks quickly and safely. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 3: Safety

    • The mains connection must correspond to the specifications in the Technical annex. • Insert the mains plug into a properly fused mains socket. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 4 Maintenance tasks which require the housing to be opened must only be carried out by specialist companies for cooling and air-conditioning or by Trotec. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 5: Information About The Device

    Without the air filter, the inside of the device will be heavily contaminated. This could reduce the performance and result in damage to the device. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 6 Transport handles Dual counter for operating hours and energy consumption (MID- compliant) optional Earthing connection Protective earth conductor Vent valve for water circuit air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 7 Louvre and air outlet Transport handles 21 a Energy meter (MID-compliant) Earthing connection Vent valve for water circuit Adjustable spacer for device protection air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 8 Louvre and air outlet Transport handles 21 a Energy meter (MID-compliant) Earthing connection Vent valve for water circuit Adjustable spacer for device protection air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 9: Transport And Storage

    After transporting the device, proceed as follows: • Set up the device in an upright position after transport. • Apply and lock the brakes at the wheels again. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 10: Assembly And Start-Up

    • 2 x 10 m connection set • 1 x manual PT 23000 S • 1 x Device • 3 x External heat exchanger • 3 x 10 m connection set • 1 x manual air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 11 • Keep air inlets and outlets as well as the exhaust air hose connection free. • Make sure that no curtains or other objects interfere with the air flow. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 12 Therefore, a little liquid exits during coupling. This loss is compensated for with the liquid from the compensation tank (5). View of the PT 15000 S: View of the PT 23000 S: 35 3 air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 13 Start-up. Note Only use monopropylene glycol and do not mix different types of glycol. The maximum glycol concentration amounts to 30 % (see technical data). air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 14: Operation

    To increase or reduce the target temperature for cooling. SET - button ON/OFF button Switches the device on or off. VENT. button To activate or deactivate ventilation mode. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 15: Available Accessories

    90 s for the purpose of air circulation – regardless of the ambient temperature and the desired room temperature. Afterwards the device resumes operation with the set values. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 16: Errors And Faults

    • Check the temperature setting at the device. Reduce the set temperature if it is higher than the room temperature. • Also check the points listed under the error message HIPS. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 17 • The wrong rotating field is set. • Exchange both phases in the mains plug. PHAS (PT 15000 S and PT 23000 S) air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 18: Maintenance

    Signature: ........Signature: ........13. Date: ........14. Date: ........15. Date: ........16. Date: ........Signature: ........Signature: ........Signature: ........Signature: ........air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 19 Do not use any aggressive cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive cleaners to dampen the cloth. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 20 Before reinserting the air filter, make sure that it is undamaged and dry! air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 21 6. Allow the filter to dry completely. Do not insert a wet filter into the device! 7. Reinsert the air filter into the device. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 22: Technical Annex

    D: front: 300 cm D: front: 400 cm Sound pressure level at a 47 dB(A) 59 dB(A) 65 dB(A) 59 dB(A) distance of 3 m (stage 1, basic device) air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 23 Circuit diagram PT 4500 S Circuit diagram PT 6500 S air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 24 Circuit diagram PT 15000 S air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 25 Circuit diagram PT 23000 S air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 26 RIGHT SIDE PANEL RAL9010 BUCC. 11 FRONT COVER RAL9010 BUCC. LEFT SIDE PANEL RAL9010 BUCC. PLASTIC HANDLE ALUMINIUM SUPPLY GRILLE LEFT HANDLE SUPPORT RAL9010 BUCC. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 27 FUSE HOLDERS + FUSES 16A PCB FOR NEW HPS LOGIC (from S.N. 1140007079) S.N. 1140007080) CONTROL PCB (from ELECTRICAL VANE CONTACTORS S.N. 1140007080) WATER OUTLET PROBE RUNNING CAPACITOR 2 uF air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 28 GLAND ELECTRIC VANE SIDE STRUCTURAL FLYING SOCKET CONNECTOR SUPPORT (FEMALE) EVAPORATOR COIL WITH REAR PANEL CONNECTOR HOLDER SHUKO PLUG REFRIGERANT DISTRIBUTOR RAL9010 BUCC. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 29 CONDENSED WATER PUMP METAL CIRCULATING PUMP CAPACITOR 16 µF PUMP SUPPORT FOR NEW PCB PLATE CONDENSER R410A SUBSTITUTION PIPE KIT FOR PERISTALTIC PUMP * COMPRESSOR + FILTER + COMPRESSOR CAPACITOR air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 30 PT 4500 S – Part 5: No. Spare part No. Spare part No. Spare part SIDE PSE PACKING BOX SOLE BOTTOM SUPERIOR PSE BOTTOM PSE air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 31 Condensed draining water connector Motor Fan with grille Condenser (coil) Foot U.E. Facsw RAL9010 BUCC. Outdoor unit propylene glycol Plug 3 pin for panel air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 32 Power Supply Cable with UK PLUG Flying socket connector (female) Power Supply Cable with SCHUKO PLUG 18 Rear panel flying connector RAL9010 BUCC. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 33 Relay with support CONTROL PCB (from S.N. 1140006914) Terminal board grey color PCB FOR NEW HPS LOGIC (from S.N. 1140006914) Defrost Thermostat CONTACTORS Metal case of Electric panel air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 34 Reservoir bracket Circulating pump capacitor 16 µF Shraeder valve * In case of replacement of the compressor it is recommended to replace the refrigerant filter (Code ACS02.013) air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 35 Coil of solenoid valve Condensed water pump with tank Body of solenoid valve Substitution pipe kit for peristaltic pump Condensed water pump metal top air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 36 Front Suction Grille RAL 9010 BUCC. Front metal cover of compressor vane Air filter (inside the grille) RAL 9010 BUCC. Display digit for new PCB air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 37 ALUMINIUM SUPPLY GRILLE RAL9010 DISPLAY DIGIT FOR NEW PCB WITHOUT BUCC. CUT BUTTONS DISPLAY PROTECTION DISPLAY LABEL DISPLAY SUPPORT KIT FIXING SCREWS FOR PIPE air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 38 PCB FOR NEW HPS LOGIC (from S N. 1130021967) DISPLAY (from S N. 1130021967) TERMINAL BOARD BLUE COLOR BLACK TEMPERATURE PROBE T1 1.8 m TERMINAL BOARD GREY COLOR GREY TEMPERATURE PROBE T2 1.8 m air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 39 CONNECTOR FOR CONDENSED WATER SUBSTITUTION PIPE KIT FOR PERISTALTIC +09 -16 DRAINAGE PUMP CONDENSED WATER PUMP METAL TOP IRON CLAMP (4 PCS) COMPRESSOR CRANKCASE HEATER air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 40 ELECTRIC VANE CAP RAL9010 BUCC. REAR ELECTRIC PANEL METAL COVER AIR FILTER RAL9010 BUCC. REAR METAL COVER OF COMPRESSOR ENERGY METER DOOR VANE RAL9010 BUCC. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 41 IP 68 PLUG CONNECTOR REAR PANEL U.E. MDB RAL9010 BULGIN 3 PIN (UE) BUCC. LATERAL PANEL RAL9010 BUCC. WATER CONNECTOR FEMALE WATER COOLER DOUBLE BLOCK 650X550 air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 42 PT 15000 S – Part 06: Spare part Spare part KIT IMBALLO U.E. MDB. PACKING KIT E.U. MDB KIT IMBALLO U.I. PACKING KIT I.U. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 43 ALUMINIUM SUPPLY GRILLE RAL9010 BUCC.. DISPLAY DIGIT FOR NEW PCB TUBULAR HANDLES RAL9005 WITHOUT CUT BUTTONS DISPLAY SUPPORT KIT FIXING SCREWS FOR PIPE air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 44 ENERGY METER FRAME GREY TEMPERATURE PROBE T2 1.8 m PCB FOR NEW HPS LOGIC BLACK TEMPERATURE PROBE T1 1.8 m CONTROL PCB WIRING CONNECTION OF THE DISPLAY air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 45 WATER RESERVOIR DEFROST THERMOSTAT SUPPORT PUMP SUPPORT FOR NEW PCB 19-1 RESERVOIR BRACKET KIT THERMOSTAT DEFROST CIRCULATING PUMP CONNECTOR FOR CONDENSED WATER DRAINAGE air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 46 INOX TRAY PIVOTING WHEEL Ø80 WITH BRAKE EYEBOLT (OPTIONAL) REAR METAL COVER OF COMPRESSOR VANE RAL9010 BUCC. EYEBOLT SUPPORT (OPTIONAL) DEFROST THERMOSTAT SUPPORT air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 47 BLOWER FAN Ø 400 WATER DRAINAGE SUPPORT HANDLE PIVOTING JOINT WATER CONNECTOR FEMALE LATERAL PANEL RAL9010 BUCC. SPACER 200mm E.U. MDB WATER COOLER DOUBLE BLOCK 650X550 air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 48 PT 23000 S – Part 6: Spare part Spare part KIT IMBALLO U.E. MDB PACKING KIT E.U. MDB KIT IMBALLO U.I. PACKING KIT I.U.. air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 49: Disposal

    2018 (PT 15000 S) 2019 (PT Year of manufacture as of: 4500 S / PT 6500 S) 2021 (PT 23000 S) Detlef von der Lieck, Managing Director air conditioner PT 4500 S / PT 6500 S / PT 15000 S / PT 23000 S...
  • Page 50 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

Table of Contents