Troubleshooting - EBECO EB-Therm 205 Manual

Hide thumbs Also See for EB-Therm 205:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

Troubleshooting

Important The underfloor heating system
is an electrical power installation and any
faults must therefore be rectified by a
qualified electrician.
Error codes
When an error occurs, EB-Therm
will turn off the heating. The display
flashes and shows a flashing error
code.
E1: Short circuit in room sensor.
E2: Breakdown in room sensor.
E3: Short circuit in floor sensor.
E4: Breakdown in floor sensor.
Test values for floor sensor
The following values apply when the
floor sensor's measurements are
checked.
Temperature Resistance
10
C
o
15
C
o
20
C
o
25
C
o
30
C
o
44
18,0 kΩ
14,7 kΩ
12,1 kΩ
10,0 kΩ
8,3 kΩ

Hide quick links: